Ultrasound assesses internal eye structures, including those obscured during a routine examination. A-scan and B-scan serve different purposes; the doctor selects the required mode.
Who the service is for
Natural lens
Patients in whom the ophthalmologist needs to assess ocular structures despite media opacity, suspected retinal detachment, vitreous haemorrhage, an intraocular mass, lens/IOL displacement or another condition where ultrasound adds information.
Symptoms / complaints
Sudden visual loss, a new curtain-like shadow, many new floaters, trauma, or lack of fundus view due to cataract or haemorrhage may lead the clinician to request ultrasound. Symptoms alone do not establish the diagnosis.
Conditions / risk groups
Dense cataract, vitreous haemorrhage, retinal/choroidal detachment, vitreous disease, intraocular or orbital masses, lens displacement, trauma and selected inflammatory conditions. The specific mode is selected clinically.
Limitations / image quality
Quality depends on operator technique, selected mode, probe position and pathology. Ultrasound does not match OCT for retinal microstructure and does not replace direct peripheral retinal examination when media are clear.
Contact lenses
Contact lenses usually do not interfere with transpalpebral B-scan, but you may be asked to remove them for the accompanying eye examination.
CT or MRI when a foreign body is suspected
If a metallic foreign body is possible, CT/MRI selection has specific safety considerations; MRI is avoided until metal is excluded.
Ultrasound does not establish a diagnosis on its own
Ultrasound does not establish a diagnosis by itself; findings require clinical interpretation.
Visual field
A normal B-scan does not exclude small peripheral retinal tears or early macular disease.
Retinal condition
B-scan does not replace OCT when microstructural retinal detail is required.
Prescribed medicines
With suspected open-globe injury, probe pressure may be hazardous; the ophthalmologist determines the imaging strategy.
Confirming the type of examination
A-scan, B-scan, IOL calculation, UBM and Doppler are not the same procedure.
Preparation
Usually no special preparation is needed. Bring prior records, report trauma or surgery, and preferably avoid eye makeup. Contact techniques or the accompanying examination may have additional requirements.
Food and drink before testing
Fasting or a special diet is usually unnecessary.
Avoid eye makeup
Avoid eye makeup when possible because coupling gel may be applied to the closed eyelid.
Results and medical records
Bring ophthalmology reports, previous ultrasound and OCT results, fundus images and postoperative records if available.
Eye injury
Tell the clinician about recent trauma, surgery, pain, suspected open-globe injury or a possible intraocular foreign body.
Pupil dilation and eye drops
Do not start new eye drops specifically for the test unless instructed. Continue prescribed medication according to your clinician’s plan.
When urgent examination is needed
Sudden major visual loss, a new curtain, flashes with many new floaters, ocular trauma, severe pain, suspected penetrating injury or chemical burn requires urgent ophthalmic assessment rather than routine ultrasound booking alone.
Limitations and safety
Ultrasound does not establish a diagnosis by itself; findings require clinical interpretation.
The clinician reviews symptoms, media opacity, trauma, prior surgery and the purpose of imaging.
Takes: 1 min
Stage 2
Select the ultrasound mode
B-scan, A-scan or another ultrasound study is selected; separate services are not treated as interchangeable.
Takes: 1 min
Stage 3
Perform the examination
For B-scan the probe is usually placed over the closed eyelid with gel and the patient may be asked to move the eye.
Takes: 1 min
Stage 4
Quality control
The examiner checks scan coverage, orientation and gain and repeats positions when needed.
Takes: 1 min
Stage 5
Interpretation and next step
The ophthalmologist correlates ultrasound with examination and other tests and determines further investigation or treatment.
Takes: 5 min
Service benefits
Imaging through cloudy media
Ultrasound helps examine internal structures when clouding prevents a clear view of the fundus.
Information about internal structures
Ultrasound images help clarify retinal position and the condition of the vitreous.
Measurements for surgical planning
Ultrasound biometry provides eye dimensions needed for selected preoperative calculations.
No X-rays
The examination uses ultrasound waves rather than X-rays.
Ultrasound method comparison, part 1
Criterion
B-scan
A-scan
US biometry / IOL
UBM
Doppler
Primary purpose
2D posterior-segment/orbital imaging
One-dimensional echoes and measurements
Axial length and IOL-related measurements
High-detail anterior-segment imaging
Blood-motion parameters in ocular/orbital vessels
Clinician receives
Image, location, shape, mobility and echogenicity
Amplitude spikes/measurements
Biometric parameters and calculation data
Detailed angle/iris/ciliary-body sections
Spectral/velocity Doppler parameters
Opaque media
Major advantage in dense cataract/vitreous haemorrhage
May be used depending on question
May support biometry; technique depends on situation
Anterior segment, different task
Does not replace B-scan anatomy
Retinal detachment
Core modality when fundus view is absent
Not the main mode for mapping detachment
Not intended
Not intended
Not intended
Vitreous / haemorrhage
Well suited for structural assessment
Additional reflectivity information
Not primary purpose
Not primary purpose
Vascular flow rather than vitreous structure
Globe measurements
Limited / device dependent
Can be used
Primary purpose
Local anterior-segment measurements
Not intended
Contact with eye
Often through closed eyelid with gel
Contact technique may be used
KazRIED’s price list includes IOL calculation using a biometer with an immersion medium
Usually immersion/contact technique
Through a closed eyelid with gel
Topical anaesthesia
Usually unnecessary transpalpebrally
May be needed for direct contact
Not required
Usually required per protocol
Usually unnecessary transpalpebrally
Ionizing radiation
No
No
No
No
No
Suspected open globe
Probe pressure may be hazardous: ophthalmologist decision
Contact is undesirable without specialist assessment
Not a priority before stabilization
Not a priority before stabilization
Not a priority before stabilization
Repeat testing
Possible as indicated
Possible as indicated
Possible if needed
Possible if needed
Possible if needed
KazRIED price
from 2 300 ₸
from 2 000 ₸
from 3 400 ₸
from 8 000 ₸
from 5 800 ₸
B-scan
Primary purpose
Clinician receives
Opaque media
Retinal detachment
Vitreous / haemorrhage
Globe measurements
Contact with eye
Topical anaesthesia
Ionizing radiation
Suspected open globe
Repeat testing
KazRIED price
2D posterior-segment/orbital imaging
Image, location, shape, mobility and echogenicity
Major advantage in dense cataract/vitreous haemorrhage
Core modality when fundus view is absent
Well suited for structural assessment
Limited / device dependent
Often through closed eyelid with gel
Usually unnecessary transpalpebrally
No
Probe pressure may be hazardous: ophthalmologist decision
Possible as indicated
from 2 300 ₸
One-dimensional echoes and measurements
Amplitude spikes/measurements
May be used depending on question
Not the main mode for mapping detachment
Additional reflectivity information
Can be used
Contact technique may be used
May be needed for direct contact
No
Contact is undesirable without specialist assessment
Possible as indicated
from 2 000 ₸
Axial length and IOL-related measurements
Biometric parameters and calculation data
May support biometry; technique depends on situation
Not intended
Not primary purpose
Primary purpose
KazRIED’s price list includes IOL calculation using a biometer with an immersion medium
Not required
No
Not a priority before stabilization
Possible if needed
from 3 400 ₸
High-detail anterior-segment imaging
Detailed angle/iris/ciliary-body sections
Anterior segment, different task
Not intended
Not primary purpose
Local anterior-segment measurements
Usually immersion/contact technique
Usually required per protocol
No
Not a priority before stabilization
Possible if needed
from 8 000 ₸
Blood-motion parameters in ocular/orbital vessels
Spectral/velocity Doppler parameters
Does not replace B-scan anatomy
Not intended
Vascular flow rather than vitreous structure
Not intended
Through a closed eyelid with gel
Usually unnecessary transpalpebrally
No
Not a priority before stabilization
Possible if needed
from 5 800 ₸
Comparison with adjacent modalities, part 2
Criterion
B-scan
Ophthalmoscopy
OCT
CT / MRI
Best at showing
Large structures, membranes, detachments, vitreous
Direct retinal view and peripheral tears when media are clear
Macular/retinal/optic nerve microstructure
Orbit, bone, trauma, deep lesions; MRI soft tissues
Works through dense cataract/vitreous haemorrhage
Yes
No / markedly limited
Usually limited
Yes, but different clinical role
Small peripheral retinal tears
May be missed
Best clinical method when examination is possible
Peripheral retina usually not the main target
Not first-line
Macular microchanges
Limited
Clinical view but less microdetail than OCT
Major strength
Not first-line
Intraocular tumours
Helps assess size and echostructure
Visible lesions when media are clear
Additional detail for selected areas
CT/MRI assess orbit and extension
Foreign body in trauma
May help; caution with open globe
Not primary
Not primary
CT often prioritized, especially with trauma/possible metal
Ionizing radiation
No
No
No
CT: yes; MRI: no
Main limitation
Operator dependence; lower microdetail than OCT
Requires adequate media clarity and access to periphery
Requires sufficient optical clarity
Cost/availability/indication; MRI contraindicated with suspected metal
Role in management
Can trigger urgent retinal/surgical pathway in selected cases
Confirms clinical localization
Details structural pathology
Clarifies trauma, orbit or disease extension when indicated
B-scan
Best at showing
Works through dense cataract/vitreous haemorrhage
Small peripheral retinal tears
Macular microchanges
Intraocular tumours
Foreign body in trauma
Ionizing radiation
Main limitation
Role in management
Large structures, membranes, detachments, vitreous
Yes
May be missed
Limited
Helps assess size and echostructure
May help; caution with open globe
No
Operator dependence; lower microdetail than OCT
Can trigger urgent retinal/surgical pathway in selected cases
Direct retinal view and peripheral tears when media are clear
No / markedly limited
Best clinical method when examination is possible
Clinical view but less microdetail than OCT
Visible lesions when media are clear
Not primary
No
Requires adequate media clarity and access to periphery
Confirms clinical localization
Macular/retinal/optic nerve microstructure
Usually limited
Peripheral retina usually not the main target
Major strength
Additional detail for selected areas
Not primary
No
Requires sufficient optical clarity
Details structural pathology
Orbit, bone, trauma, deep lesions; MRI soft tissues
Yes, but different clinical role
Not first-line
Not first-line
CT/MRI assess orbit and extension
CT often prioritized, especially with trauma/possible metal
CT: yes; MRI: no
Cost/availability/indication; MRI contraindicated with suspected metal
Clarifies trauma, orbit or disease extension when indicated
Book an appointment
Book ocular ultrasound
Book the examination if your ophthalmologist recommended A-scan, B-scan or another ultrasound study. When booking, provide the exact study name from the referral so the correct service is selected.
IOL calculation using an immersion biometer (per eye)from 3 400 ₸
Doppler ultrasound of ocular and orbital vessels (per eye)from 5 800 ₸
Our services, payable in installmentsTake care of your vision today and pay for our services in installments. Choose installment terms and a payment schedule that suit you.
Ocular Ultrasound — Ultrasound Examination of the Eye
Standard ocular ultrasound uses ultrasound waves reflected from tissues. It helps clinicians determine the location and characteristics of changes within the eye and certain orbital structures.
What does a B-scan show?
A B-scan produces a two-dimensional image and helps assess the vitreous, retina, choroid, posterior wall of the eye, and certain orbital structures.
The examination is particularly useful when the optical media are opaque, limiting conventional ophthalmoscopy or fundus photography.
What is an A-scan used for?
An A-scan displays the amplitude of echo signals in one dimension and is used for measurement and echographic assessment.
What should be considered?
Intraocular lens (IOL) power calculation, ultrasound biomicroscopy of the anterior segment, and vascular Doppler ultrasound are separate examinations. They are not automatically included in a standard B-scan.
Ultrasound helps locate and characterize abnormalities, but it does not replace a clinical examination, optical coherence tomography (OCT), ophthalmoscopy, computed tomography (CT), or magnetic resonance imaging (MRI) when those methods provide more appropriate information.
Perform the examination
For B-scan the probe is usually placed over the closed eyelid with gel and the patient may be asked to move the eye. Contact techniques follow a separate protocol.
Additional advice and situations
If the B-scan shows no significant abnormalities
The findings are assessed in the context of the reason for referral. If symptoms persist, the clinician may recommend OCT, a retinal examination, or other diagnostic tests.
If a detachment or a suspicious membrane is detected
The patient is referred for urgent assessment by a retinal specialist or vitreoretinal surgeon. The degree of urgency is determined clinically.
If an intraocular mass is detected
Additional imaging, consultation with an ocular oncologist, and serial measurements of the mass may be required.
If the examination quality is insufficient
Scanning is repeated in additional positions, or another imaging method is selected.
If the examination is performed for follow-up
Comparable scans, measurements, and echographic characteristics are compared with those from previous examinations.
Ultrasound biomicroscopy (UBM)
A separate examination of the anterior segment of the eye.
Doppler ultrasound of the ocular and orbital vessels
A separate Doppler examination of the blood vessels of the eye and orbit.
Facts and offers
Kazakhstan’s first specialized ophthalmology institute, operating since 1933.
Modern diagnostics and surgery using world-class equipment.
Leading ophthalmologists in Kazakhstan, scientists and experienced surgeons.
More than 30,000 operations and around 270,000 consultations annually.
Kazakhstan’s first specialized ophthalmology institute, operating since 1933.
Modern diagnostics and surgery using world-class equipment.
Leading ophthalmologists in Kazakhstan, scientists and experienced surgeons.
More than 30,000 operations and around 270,000 consultations annually.
Kazakhstan’s first specialized ophthalmology institute, operating since 1933.
Modern diagnostics and surgery using world-class equipment.
Leading ophthalmologists in Kazakhstan, scientists and experienced surgeons.
More than 30,000 operations and around 270,000 consultations annually.
It is an ultrasound examination of the eye and, when required, selected orbital structures. Reflected sound waves are converted into images or measurement data.
How does B-scan differ from A-scan?
B-scan provides a two-dimensional image for anatomical and pathological assessment. A-scan displays echo amplitude in one dimension and is used for selected measurements and tissue-reflectivity assessment.
When is B-scan particularly useful?
B-scan is particularly useful when the fundus cannot be adequately visualized because of dense cataract, vitreous haemorrhage, corneal opacity, hyphema or other media opacity.
What can B-scan show in vitreous haemorrhage?
It can demonstrate echoes within the vitreous and help assess associated findings such as retinal detachment, posterior vitreous detachment, tractional membranes or an intraocular mass.
Can ultrasound detect retinal detachment?
Yes. B-scan is widely used to detect and assess retinal detachment, particularly when the fundus view is obscured. When the retina can be examined directly, peripheral tears are additionally assessed during a dilated retinal examination.
Does ultrasound replace OCT?
No. OCT provides high-resolution layer-by-layer imaging of the retina and optic nerve when the optical media are sufficiently clear. B-scan has lower microstructural resolution but can image through significant media opacity.
Does ultrasound replace a fundus examination?
No. When the fundus is visible, ophthalmoscopy allows direct assessment of the retina and its periphery. Ultrasound is particularly useful when direct visualization is limited.
Does ocular ultrasound diagnose glaucoma?
No. Ultrasound is not a primary test for glaucoma. Diagnosis is based on a combination of intraocular pressure, optic nerve assessment, visual fields, OCT and other clinical findings.
Does ultrasound show cataract?
Ultrasound may provide information about the lens and its position, but cataract is usually diagnosed by slit-lamp examination. With dense cataract, B-scan helps assess structures behind the opaque lens.
Can ultrasound show lens dislocation or subluxation?
Yes. Ultrasound can help assess the position of the natural lens or an intraocular lens, particularly when optical visualization is difficult.