Kazakh Research Institute of Eye Diseases

Book an appointment

Science and Practice for Vision Preservation

We combine scientific research and clinical practice to tailor treatment to the diagnosis and individual characteristics of each patient.

Our doctors

A team of experienced doctors across different specialties who listen carefully, support you and choose the best solution for your vision

All doctorsThe full list of doctors is available here!

Our institute in numbers

Modern diagnostics and treatment of eye conditions for children and adults, with an individual approach and care for your vision

>270 000 Consultations per year
>140 Number of doctors
>5000 Scientific publications
>30 000 Operations per year
Learn more about us

Our equipment

Modern equipment from leading global manufacturers

Alcon ARGOS® с Image Guidance United States

Alcon ARGOS® Optical Biometer with Image Guidance

Alcon ARGOS® Optical Biometer with Image Guidance Overview The Alcon ARGOS® is a non-contact optical biometer based on Swept Source Optical Coherence Tomography (SS-OCT). The system acquires key ocular biometric measurements and performs calculations used to determine appropriate intraocular lens power and type for cataract surgery. ARGOS® uses a segmented axial length calculation method and integrates with Image Guidance by Alcon® to transfer preoperative information from the clinic to the operating room. Manufacturer ARGOS® is manufactured by MOVU Inc., Santa Clara, California, USA. In 2019, MOVU and Alcon entered into an agreement to integrate ARGOS® into the Alcon cataract surgery ecosystem. ARGOS® with Image Guidance is distributed and integrated by Alcon. Availability of software functions, IOL formulas and integration options varies by market and system configuration. Applications Cataract surgery and IOL calculation ARGOS® is intended to acquire ocular measurements and perform calculations used to determine the appropriate IOL power and type for implantation. The system measures: axial length; keratometry; central corneal thickness; anterior chamber depth; aqueous depth; lens thickness; white-to-white corneal diameter; pupil size; angle kappa coordinates Px and Py. Depending on installed software and Alcon Vision Planner configuration, available IOL formulas can include Barrett Universal II, Barrett Toric, Barrett True K, SRK/T, Holladay, Haigis and Hoffer Q. Dense and mature cataracts Swept Source OCT combined with Enhanced Retina Visualization (ERV) is designed to improve acquisition of the retinal signal through significant media opacity. In a comparative study of 51 eyes with dense cataracts, axial length acquisition success was: ARGOS®: 100%; IOLMaster 700: 98.04%; Anterion: 94.12%; Pentacam AXL: 60.78%. Three eyes could not initially be measured with ARGOS® in standard mode, but axial length was successfully obtained after ERV mode was used. The 100% figure therefore describes the results of that particular study with ERV used when required and should not be interpreted as a guarantee in every dense cataract. In an earlier comparative study, ARGOS® successfully obtained axial length in 96% of cases, compared with 79% for an OLCR-based device and 77% for a PCI-based device. Eyes with long axial length Segmented axial length measurement can be particularly relevant in unusually short or long eyes because individual ocular media are calculated using their respective refractive indices. In a study of 126 cataract eyes with axial length greater than 25 mm, both ARGOS® and IOLMaster 700 achieved a 100% acquisition rate. Within-subject standard deviation for axial length was: ARGOS®: 0.01 mm; IOLMaster 700: 0.03 mm. The investigators also noted that measurements from different biometers should not automatically be regarded as interchangeable. Reference imaging Reference Image functionality is intended for preoperative and postoperative image capture. During preoperative measurement, ARGOS® captures a reference image containing the patient's individual iris and limbal landmarks. In a compatible Image Guidance workflow, the image and surgical plan can be transferred to the operating room for: cyclotorsion compensation; digital surgical-axis guidance; toric IOL alignment; real-time procedural navigation. In VERION® configurations, the reference image can be transferred to a compatible Digital Marker. In the current Alcon ecosystem, ARGOS® image guidance can also integrate with Alcon Vision Suite and NGENUITY®. Technology and features Sum-of-Segments axial length calculation ARGOS® does not calculate total axial length by converting the entire optical path using one average refractive index. Instead, the system measures individual ocular segments: cornea; aqueous; crystalline lens; vitreous. A specific refractive index is applied to each segment, after which the geometric segment lengths are added to derive total axial length. This approach accounts for the different optical media within an individual eye and can affect IOL calculations, particularly in eyes with atypical axial length. Swept Source OCT ARGOS® uses Swept Source OCT with: central wavelength: approximately 1060 nm; bandwidth: approximately 20 nm; scanning speed: approximately 3000 A-lines per second. The system acquires two-dimensional OCT data and provides imaging from the cornea to the retina. Alcon states that the 3000 A-lines/s scanning rate is 1.5 times the 2000 A-lines/s rate used for comparison with IOLMaster 700. Biometric capture time is less than one second and can be as low as approximately 0.6 seconds under applicable conditions. Enhanced Retina Visualization Enhanced Retina Visualization is intended for situations in which the retinal signal is insufficient, including significant media opacity. ERV reconfigures the internal optical system to enhance the retinal signal. Alcon describes an approximately tenfold increase in retinal signal compared with normal mode. The function is designed to improve the likelihood of successful axial length acquisition but does not guarantee successful measurement in every dense cataract. Auto-capture ARGOS® incorporates an Auto-Capture mode. Once the system detects optimal patient alignment and appropriate acquisition conditions, measurements are captured automatically without an additional operator command. This helps standardize biometric acquisition and reduces manual steps during the examination. Alignment and fixation guidance Angle-to-angle and cornea-to-retina SS-OCT imaging provide real-time guidance during biometric acquisition. The operator can assess: ocular alignment; fixation; measurement-axis positioning; anatomical structures used for biometry. This provides an additional quality check before the measurements are used for IOL calculation. Measured parameters ARGOS® provides measurements including: Axial Length (AL); Keratometry (K); Central Corneal Thickness (CCT); Anterior Chamber Depth (ACD); Aqueous Depth (AD); Lens Thickness (LT); White-to-White (WTW); Pupil Diameter (PD); Angle Kappa coordinates Px and Py. Measurement repeatability In a clinical study involving 107 eyes, ARGOS® demonstrated low interset variability for several biometric measurements. Reported mean interset differences included: 0.01 mm for axial length; 0.01 mm for central corneal thickness; 0.01 mm for aqueous depth and anterior chamber depth; 0.03 mm for lens thickness. These values describe performance under the conditions of the study and should not be interpreted as guaranteed measurement accuracy in every patient. Integration into the Alcon ecosystem ARGOS® with Image Guidance supports digital transfer of diagnostic information from the clinic to the operating room. Depending on system configuration, integration can include: Alcon Vision Planner; VERION® Digital Marker; NGENUITY® 3D Visualization System; LenSx® Laser System; other compatible components of the Alcon Vision Suite. The preoperative reference image and surgical plan allow the patient's individual iris and limbal landmarks to be used for digital guidance and cyclotorsion compensation. Technical specifications Type: non-contact optical biometer based on Swept Source OCT. OCT acquisition: two-dimensional ocular imaging. Central wavelength: approximately 1060 nm. Bandwidth: approximately 20 nm. Scan speed: approximately 3000 A-lines per second. Biometric capture time: less than 1 second, as low as approximately 0.6 seconds under applicable conditions. Axial length calculation: Sum-of-Segments using specific refractive indices for individual ocular media. Axial length: SS-OCT measurement. Keratometry: SS-OCT-enhanced keratometry. Measured parameters: AL, K, CCT, ACD, AD, LT, WTW, PD and angle kappa coordinates. Enhanced Retina Visualization: available for enhanced retinal signal when standard acquisition is difficult. Acquisition mode: automatic when optimal alignment is achieved. Reference Image: preoperative and postoperative image capture. Examination method: non-contact. Integration: Alcon Image Guidance and compatible Alcon Vision Suite components depending on configuration. Benefits For the surgeon and clinic segmented axial length calculation using individual refractive indices for different ocular media; high axial length acquisition rates in dense cataracts reported in comparative studies; Enhanced Retina Visualization for difficult retinal signal acquisition; biometric data capture in less than one second; automatic capture when optimal alignment is achieved; multiple biometric parameters acquired within one workflow; preoperative reference imaging for digital surgical guidance; cyclotorsion compensation with compatible Image Guidance systems; digital transfer of measurements and surgical planning data within compatible Alcon systems. For the patient non-contact examination; standard optical biometry does not require topical anesthesia; biometric data can be acquired in less than one second after appropriate positioning; ERV improves the ability to obtain axial length through significant lens opacity; digital data transfer reduces the need for repeated manual transcription between the diagnostic clinic and operating room.

Learn more
Alcon ARGOS® с Image Guidance United States

Alcon ARGOS® Optical Biometer with Image Guidance

Manufacturer: Alcon
Country of manufacture: United States

Alcon ARGOS® Optical Biometer with Image Guidance

Overview

The Alcon ARGOS® is a non-contact optical biometer based on Swept Source Optical Coherence Tomography (SS-OCT). The system acquires key ocular biometric measurements and performs calculations used to determine appropriate intraocular lens power and type for cataract surgery.

ARGOS® uses a segmented axial length calculation method and integrates with Image Guidance by Alcon® to transfer preoperative information from the clinic to the operating room.

Manufacturer

ARGOS® is manufactured by MOVU Inc., Santa Clara, California, USA.

In 2019, MOVU and Alcon entered into an agreement to integrate ARGOS® into the Alcon cataract surgery ecosystem. ARGOS® with Image Guidance is distributed and integrated by Alcon.

Availability of software functions, IOL formulas and integration options varies by market and system configuration.

Applications

Cataract surgery and IOL calculation

ARGOS® is intended to acquire ocular measurements and perform calculations used to determine the appropriate IOL power and type for implantation.

The system measures:

  • axial length;
  • keratometry;
  • central corneal thickness;
  • anterior chamber depth;
  • aqueous depth;
  • lens thickness;
  • white-to-white corneal diameter;
  • pupil size;
  • angle kappa coordinates Px and Py.

Depending on installed software and Alcon Vision Planner configuration, available IOL formulas can include Barrett Universal II, Barrett Toric, Barrett True K, SRK/T, Holladay, Haigis and Hoffer Q.

Dense and mature cataracts

Swept Source OCT combined with Enhanced Retina Visualization (ERV) is designed to improve acquisition of the retinal signal through significant media opacity.

In a comparative study of 51 eyes with dense cataracts, axial length acquisition success was:

  • ARGOS®: 100%;
  • IOLMaster 700: 98.04%;
  • Anterion: 94.12%;
  • Pentacam AXL: 60.78%.

Three eyes could not initially be measured with ARGOS® in standard mode, but axial length was successfully obtained after ERV mode was used. The 100% figure therefore describes the results of that particular study with ERV used when required and should not be interpreted as a guarantee in every dense cataract.

In an earlier comparative study, ARGOS® successfully obtained axial length in 96% of cases, compared with 79% for an OLCR-based device and 77% for a PCI-based device.

Eyes with long axial length

Segmented axial length measurement can be particularly relevant in unusually short or long eyes because individual ocular media are calculated using their respective refractive indices.

In a study of 126 cataract eyes with axial length greater than 25 mm, both ARGOS® and IOLMaster 700 achieved a 100% acquisition rate.

Within-subject standard deviation for axial length was:

  • ARGOS®: 0.01 mm;
  • IOLMaster 700: 0.03 mm.

The investigators also noted that measurements from different biometers should not automatically be regarded as interchangeable.

Reference imaging

Reference Image functionality is intended for preoperative and postoperative image capture.

During preoperative measurement, ARGOS® captures a reference image containing the patient's individual iris and limbal landmarks.

In a compatible Image Guidance workflow, the image and surgical plan can be transferred to the operating room for:

  • cyclotorsion compensation;
  • digital surgical-axis guidance;
  • toric IOL alignment;
  • real-time procedural navigation.

In VERION® configurations, the reference image can be transferred to a compatible Digital Marker. In the current Alcon ecosystem, ARGOS® image guidance can also integrate with Alcon Vision Suite and NGENUITY®.

Technology and features

Sum-of-Segments axial length calculation

ARGOS® does not calculate total axial length by converting the entire optical path using one average refractive index.

Instead, the system measures individual ocular segments:

  • cornea;
  • aqueous;
  • crystalline lens;
  • vitreous.

A specific refractive index is applied to each segment, after which the geometric segment lengths are added to derive total axial length.

This approach accounts for the different optical media within an individual eye and can affect IOL calculations, particularly in eyes with atypical axial length.

Swept Source OCT

ARGOS® uses Swept Source OCT with:

  • central wavelength: approximately 1060 nm;
  • bandwidth: approximately 20 nm;
  • scanning speed: approximately 3000 A-lines per second.

The system acquires two-dimensional OCT data and provides imaging from the cornea to the retina.

Alcon states that the 3000 A-lines/s scanning rate is 1.5 times the 2000 A-lines/s rate used for comparison with IOLMaster 700. Biometric capture time is less than one second and can be as low as approximately 0.6 seconds under applicable conditions.

Enhanced Retina Visualization

Enhanced Retina Visualization is intended for situations in which the retinal signal is insufficient, including significant media opacity.

ERV reconfigures the internal optical system to enhance the retinal signal. Alcon describes an approximately tenfold increase in retinal signal compared with normal mode.

The function is designed to improve the likelihood of successful axial length acquisition but does not guarantee successful measurement in every dense cataract.

Auto-capture

ARGOS® incorporates an Auto-Capture mode.

Once the system detects optimal patient alignment and appropriate acquisition conditions, measurements are captured automatically without an additional operator command.

This helps standardize biometric acquisition and reduces manual steps during the examination.

Alignment and fixation guidance

Angle-to-angle and cornea-to-retina SS-OCT imaging provide real-time guidance during biometric acquisition.

The operator can assess:

  • ocular alignment;
  • fixation;
  • measurement-axis positioning;
  • anatomical structures used for biometry.

This provides an additional quality check before the measurements are used for IOL calculation.

Measured parameters

ARGOS® provides measurements including:

  • Axial Length (AL);
  • Keratometry (K);
  • Central Corneal Thickness (CCT);
  • Anterior Chamber Depth (ACD);
  • Aqueous Depth (AD);
  • Lens Thickness (LT);
  • White-to-White (WTW);
  • Pupil Diameter (PD);
  • Angle Kappa coordinates Px and Py.

Measurement repeatability

In a clinical study involving 107 eyes, ARGOS® demonstrated low interset variability for several biometric measurements.

Reported mean interset differences included:

  • 0.01 mm for axial length;
  • 0.01 mm for central corneal thickness;
  • 0.01 mm for aqueous depth and anterior chamber depth;
  • 0.03 mm for lens thickness.

These values describe performance under the conditions of the study and should not be interpreted as guaranteed measurement accuracy in every patient.

Integration into the Alcon ecosystem

ARGOS® with Image Guidance supports digital transfer of diagnostic information from the clinic to the operating room.

Depending on system configuration, integration can include:

  • Alcon Vision Planner;
  • VERION® Digital Marker;
  • NGENUITY® 3D Visualization System;
  • LenSx® Laser System;
  • other compatible components of the Alcon Vision Suite.

The preoperative reference image and surgical plan allow the patient's individual iris and limbal landmarks to be used for digital guidance and cyclotorsion compensation.

Technical specifications

  • Type: non-contact optical biometer based on Swept Source OCT.
  • OCT acquisition: two-dimensional ocular imaging.
  • Central wavelength: approximately 1060 nm.
  • Bandwidth: approximately 20 nm.
  • Scan speed: approximately 3000 A-lines per second.
  • Biometric capture time: less than 1 second, as low as approximately 0.6 seconds under applicable conditions.
  • Axial length calculation: Sum-of-Segments using specific refractive indices for individual ocular media.
  • Axial length: SS-OCT measurement.
  • Keratometry: SS-OCT-enhanced keratometry.
  • Measured parameters: AL, K, CCT, ACD, AD, LT, WTW, PD and angle kappa coordinates.
  • Enhanced Retina Visualization: available for enhanced retinal signal when standard acquisition is difficult.
  • Acquisition mode: automatic when optimal alignment is achieved.
  • Reference Image: preoperative and postoperative image capture.
  • Examination method: non-contact.
  • Integration: Alcon Image Guidance and compatible Alcon Vision Suite components depending on configuration.

Benefits

For the surgeon and clinic

  • segmented axial length calculation using individual refractive indices for different ocular media;
  • high axial length acquisition rates in dense cataracts reported in comparative studies;
  • Enhanced Retina Visualization for difficult retinal signal acquisition;
  • biometric data capture in less than one second;
  • automatic capture when optimal alignment is achieved;
  • multiple biometric parameters acquired within one workflow;
  • preoperative reference imaging for digital surgical guidance;
  • cyclotorsion compensation with compatible Image Guidance systems;
  • digital transfer of measurements and surgical planning data within compatible Alcon systems.

For the patient

  • non-contact examination;
  • standard optical biometry does not require topical anesthesia;
  • biometric data can be acquired in less than one second after appropriate positioning;
  • ERV improves the ability to obtain axial length through significant lens opacity;
  • digital data transfer reduces the need for repeated manual transcription between the diagnostic clinic and operating room.
Alcon NGENUITY® United States

Alcon NGENUITY® 3D Visualization System

Alcon NGENUITY® 3D Visualization System Overview The Alcon NGENUITY® is a digital stereoscopic 3D visualization system for heads-up ophthalmic microsurgery. A stereoscopic digital camera is attached to a compatible surgical microscope and transmits the surgical field to a 55-inch 4K OLED display. The surgeon performs the procedure while viewing the stereoscopic image through passive polarized 3D glasses rather than continuously working through the microscope oculars. The system is used for both anterior and posterior segment surgery and can be integrated with other components of the Alcon surgical ecosystem. Manufacturer Alcon. NGENUITY® technology was originally developed in collaboration with TrueVision® 3D Surgical in the United States. Alcon began distributing NGENUITY® under an exclusive agreement with TrueVision in 2016 and acquired 100% of TrueVision Systems, Inc. on December 19, 2018. NGENUITY® acts as an adjunct to a compatible surgical microscope and provides real-time magnified stereoscopic visualization of the surgical field. Availability of software functions, Digital Image Guidance and integration capabilities varies by software version, system configuration and market. Applications Vitreoretinal surgery NGENUITY® is used for digital visualization of the posterior segment during vitreoretinal surgery. Applications can include: vitrectomy; internal limiting membrane peeling; epiretinal membrane removal; macular hole surgery; retinal detachment surgery; surgical management of complications of diabetic retinopathy; other retinal and vitreous microsurgical procedures. Digital image processing enables adjustment of color, contrast and brightness and provides specialized visualization modes for selected tissues and dyes. Cataract surgery NGENUITY® provides heads-up visualization during cataract surgery, including: capsulorhexis; phacoemulsification; irrigation and aspiration; IOL implantation; toric IOL alignment when used with a compatible digital image guidance system. Current software includes dedicated modes designed to enhance visualization of the capsule and other anterior segment structures. When integrated with Alcon Digital Image Guidance, diagnostic information and surgical guidance can be displayed on the primary surgical screen. Minimally invasive glaucoma surgery NGENUITY® supports anterior chamber visualization during minimally invasive glaucoma surgery. Current software includes MIGS Mode, designed to digitally enhance contrast of anterior chamber angle structures. According to Alcon, this mode can provide up to 34% greater local contrast under specified conditions compared with surgical microscopes and digital systems without the corresponding image processing. This can assist visualization of the trabecular meshwork and positioning of compatible MIGS devices. Teaching and team collaboration The large stereoscopic display allows other members of the operating room team to view the same surgical field as the surgeon. This can support: resident and surgeon training; assistant coordination; demonstration of individual surgical steps; recording and postoperative review of procedures. Compatible passive 3D glasses are used by team members for stereoscopic viewing. Technology and features Stereoscopic digital camera NGENUITY® uses a stereoscopic digital surgical camera. The current system incorporates: two Full HD sensors; 1920 × 1080 resolution per sensor; 60 frames per second for each eye; real-time digital image processing. The two independent images create a stereoscopic image that provides depth perception across the surgical field. The camera mounts to a compatible surgical microscope and allows the display to become the surgeon's primary visualization interface. High-speed digital processing A high-performance processor handles both video streams in real time. Digital adjustments include: brightness; contrast; color; color temperature; magnification; parameters of specialized visualization modes. The system supports personalized settings, video playback and multiple image display options. 55-inch 4K OLED display NGENUITY® uses a 55-inch OLED surgical display with 4K UHD resolution: resolution: 3840 × 2160; screen size: 55 inches; frame rate: 60 fps for each eye; stereoscopic viewing through passive polarized 3D glasses. Compared with LCD technology, OLED provides greater contrast, a wider color range and improved display of dark image regions. The display and camera resolutions should be distinguished: the display is 4K, while the stereoscopic camera uses two 1920 × 1080 Full HD sensors. Depth of field and digital magnification Digital visualization enables magnification to be modified independently of conventional ocular viewing. According to Alcon, under specified comparison conditions with analog surgical microscopes, NGENUITY® provides: up to 48% greater magnification; up to 5 times greater depth of field; up to 42% greater depth resolution. These maximum values were obtained under defined technical conditions, including maximum system magnification, a specified camera aperture and viewing distance, and therefore should not be interpreted as constant values during every procedure. Extended depth of field can reduce the need for frequent manual refocusing during microsurgical maneuvers. Surgical illumination level High camera sensitivity and real-time digital processing can allow lower microscope or endoillumination levels to be used in selected surgical settings. Alcon reports operation at illumination levels up to four times lower under specified conditions without compromising visual outcomes in the studies referenced by the manufacturer. Lower illumination may theoretically reduce ocular light exposure, but the actual level is selected by the surgeon according to the procedure, optical system and required visualization. Use of NGENUITY® should not be interpreted as a guarantee against retinal phototoxicity. Digital Detection and specialized modes The current NGENUITY® 1.5 software platform includes dedicated digital image enhancement modes. Depending on configuration, these include: Tissue Detail Mode; Capsule Clarity Mode; MIGS Mode; Blue Boost Mode; Performance Green Mode; Digital Image Guidance. Mode settings can be further personalized in real time. The earlier DATAFUSION™ version introduced in 2018 included four preset imaging profiles, so the number and type of available modes depend on the installed software generation. DATAFUSION™ DATAFUSION™ enables information exchange between NGENUITY® and compatible Alcon surgical platforms. When integrated with the CONSTELLATION® Vision System, real-time parameters displayed on the main 3D screen can include: intraocular pressure; flow rate; infusion pressure; vitrectomy cut rate; laser settings; other surgical system parameters. This allows the surgeon to view the surgical field and key system information on a single display rather than repeatedly looking between separate screens. Alcon Digital Image Guidance Current NGENUITY® configurations can support Digital Image Guidance within the Alcon digital ecosystem. When integrated with the ARGOS® Biometer and compatible software, preoperative information can be transferred to the operating room and used for: ocular image registration; cyclotorsion compensation; digital surgical guidance; toric IOL positioning; digital support during selected stages of cataract surgery. Specific functions depend on the installed software version and system configuration. Recording and image distribution NGENUITY® supports: 2D and 3D video recording; video playback; simultaneous 2D and 3D streaming to multiple displays; Picture-in-Picture; split-screen processing; recording for teaching and documentation. Technical specifications Type: digital stereoscopic 3D visualization system for ophthalmic microsurgery. Operating format: heads-up. Intended role: adjunct to a compatible surgical microscope. Camera: stereoscopic digital surgical camera. Sensors: 2 × Full HD. Sensor resolution: 1920 × 1080. Camera frame rate: 60 fps per eye. Processing: high-speed digital image processor. Display technology: OLED. Display size: 55 inches. Display resolution: 4K UHD, 3840 × 2160. Display frame rate: 60 fps per eye. 3D viewing: passive polarized glasses. Depth of field: up to 5× compared with specified analog microscopes under defined Alcon test conditions. Magnification: up to 48% greater compared with specified analog microscopes under defined conditions. Depth resolution: up to 42% greater under corresponding comparison conditions. Illumination: lower illumination settings can be used; Alcon reports up to 4× lower levels under specified conditions. Digital modes: Tissue Detail, Capsule Clarity, MIGS, Blue Boost, Performance Green and others depending on software version. Recording: 2D / 3D. Playback: real-time and recorded material. Additional display options: multiple displays, Picture-in-Picture and split screen. Integration: DATAFUSION™, Alcon Digital Image Guidance and compatible Alcon Vision Suite components. Benefits For the surgeon and surgical team heads-up viewing enables the surgeon to work from the primary display rather than continuously leaning toward microscope oculars; the large 3D display provides a shared surgical view for the surgeon and operating room team; up to 5× extended depth of field under specified technical conditions can reduce frequent manual refocusing; digital magnification can be up to 48% greater in the specified comparison with analog microscopes; digital enhancement modes allow color, contrast and detail to be adapted to different stages of surgery; DATAFUSION™ displays compatible surgical platform parameters on the primary screen; Digital Image Guidance can support an integrated cataract surgery workflow; procedures can be recorded in 2D or 3D; the shared view supports teaching and collaborative review. In studies and surveys referenced by Alcon, surgeons using NGENUITY® were substantially more likely to report reduced discomfort or pain, improved posture and improved overall ergonomic comfort compared with conventional ocular-based microscopy. For the patient digital visualization may allow lower surgical illumination to be used while maintaining the visualization required by the surgeon; extended depth of field and digital image processing support detailed visualization of small structures; integrated digital guidance can make preoperative information available during surgery; lower light levels may reduce ocular light exposure, although the required illumination is determined by the surgeon for each individual procedure.

Learn more
Alcon NGENUITY® United States

Alcon NGENUITY® 3D Visualization System

Manufacturer: Alcon Laboratories, Inc.
Country of manufacture: United States

Alcon NGENUITY® 3D Visualization System

Overview

The Alcon NGENUITY® is a digital stereoscopic 3D visualization system for heads-up ophthalmic microsurgery.

A stereoscopic digital camera is attached to a compatible surgical microscope and transmits the surgical field to a 55-inch 4K OLED display. The surgeon performs the procedure while viewing the stereoscopic image through passive polarized 3D glasses rather than continuously working through the microscope oculars.

The system is used for both anterior and posterior segment surgery and can be integrated with other components of the Alcon surgical ecosystem.

Manufacturer

Alcon.

NGENUITY® technology was originally developed in collaboration with TrueVision® 3D Surgical in the United States.

Alcon began distributing NGENUITY® under an exclusive agreement with TrueVision in 2016 and acquired 100% of TrueVision Systems, Inc. on December 19, 2018.

NGENUITY® acts as an adjunct to a compatible surgical microscope and provides real-time magnified stereoscopic visualization of the surgical field.

Availability of software functions, Digital Image Guidance and integration capabilities varies by software version, system configuration and market.

Applications

Vitreoretinal surgery

NGENUITY® is used for digital visualization of the posterior segment during vitreoretinal surgery.

Applications can include:

  • vitrectomy;
  • internal limiting membrane peeling;
  • epiretinal membrane removal;
  • macular hole surgery;
  • retinal detachment surgery;
  • surgical management of complications of diabetic retinopathy;
  • other retinal and vitreous microsurgical procedures.

Digital image processing enables adjustment of color, contrast and brightness and provides specialized visualization modes for selected tissues and dyes.

Cataract surgery

NGENUITY® provides heads-up visualization during cataract surgery, including:

  • capsulorhexis;
  • phacoemulsification;
  • irrigation and aspiration;
  • IOL implantation;
  • toric IOL alignment when used with a compatible digital image guidance system.

Current software includes dedicated modes designed to enhance visualization of the capsule and other anterior segment structures.

When integrated with Alcon Digital Image Guidance, diagnostic information and surgical guidance can be displayed on the primary surgical screen.

Minimally invasive glaucoma surgery

NGENUITY® supports anterior chamber visualization during minimally invasive glaucoma surgery.

Current software includes MIGS Mode, designed to digitally enhance contrast of anterior chamber angle structures.

According to Alcon, this mode can provide up to 34% greater local contrast under specified conditions compared with surgical microscopes and digital systems without the corresponding image processing.

This can assist visualization of the trabecular meshwork and positioning of compatible MIGS devices.

Teaching and team collaboration

The large stereoscopic display allows other members of the operating room team to view the same surgical field as the surgeon.

This can support:

  • resident and surgeon training;
  • assistant coordination;
  • demonstration of individual surgical steps;
  • recording and postoperative review of procedures.

Compatible passive 3D glasses are used by team members for stereoscopic viewing.

Technology and features

Stereoscopic digital camera

NGENUITY® uses a stereoscopic digital surgical camera.

The current system incorporates:

  • two Full HD sensors;
  • 1920 × 1080 resolution per sensor;
  • 60 frames per second for each eye;
  • real-time digital image processing.

The two independent images create a stereoscopic image that provides depth perception across the surgical field.

The camera mounts to a compatible surgical microscope and allows the display to become the surgeon's primary visualization interface.

High-speed digital processing

A high-performance processor handles both video streams in real time.

Digital adjustments include:

  • brightness;
  • contrast;
  • color;
  • color temperature;
  • magnification;
  • parameters of specialized visualization modes.

The system supports personalized settings, video playback and multiple image display options.

55-inch 4K OLED display

NGENUITY® uses a 55-inch OLED surgical display with 4K UHD resolution:

  • resolution: 3840 × 2160;
  • screen size: 55 inches;
  • frame rate: 60 fps for each eye;
  • stereoscopic viewing through passive polarized 3D glasses.

Compared with LCD technology, OLED provides greater contrast, a wider color range and improved display of dark image regions.

The display and camera resolutions should be distinguished: the display is 4K, while the stereoscopic camera uses two 1920 × 1080 Full HD sensors.

Depth of field and digital magnification

Digital visualization enables magnification to be modified independently of conventional ocular viewing.

According to Alcon, under specified comparison conditions with analog surgical microscopes, NGENUITY® provides:

  • up to 48% greater magnification;
  • up to 5 times greater depth of field;
  • up to 42% greater depth resolution.

These maximum values were obtained under defined technical conditions, including maximum system magnification, a specified camera aperture and viewing distance, and therefore should not be interpreted as constant values during every procedure.

Extended depth of field can reduce the need for frequent manual refocusing during microsurgical maneuvers.

Surgical illumination level

High camera sensitivity and real-time digital processing can allow lower microscope or endoillumination levels to be used in selected surgical settings.

Alcon reports operation at illumination levels up to four times lower under specified conditions without compromising visual outcomes in the studies referenced by the manufacturer.

Lower illumination may theoretically reduce ocular light exposure, but the actual level is selected by the surgeon according to the procedure, optical system and required visualization.

Use of NGENUITY® should not be interpreted as a guarantee against retinal phototoxicity.

Digital Detection and specialized modes

The current NGENUITY® 1.5 software platform includes dedicated digital image enhancement modes.

Depending on configuration, these include:

  • Tissue Detail Mode;
  • Capsule Clarity Mode;
  • MIGS Mode;
  • Blue Boost Mode;
  • Performance Green Mode;
  • Digital Image Guidance.

Mode settings can be further personalized in real time.

The earlier DATAFUSION™ version introduced in 2018 included four preset imaging profiles, so the number and type of available modes depend on the installed software generation.

DATAFUSION™

DATAFUSION™ enables information exchange between NGENUITY® and compatible Alcon surgical platforms.

When integrated with the CONSTELLATION® Vision System, real-time parameters displayed on the main 3D screen can include:

  • intraocular pressure;
  • flow rate;
  • infusion pressure;
  • vitrectomy cut rate;
  • laser settings;
  • other surgical system parameters.

This allows the surgeon to view the surgical field and key system information on a single display rather than repeatedly looking between separate screens.

Alcon Digital Image Guidance

Current NGENUITY® configurations can support Digital Image Guidance within the Alcon digital ecosystem.

When integrated with the ARGOS® Biometer and compatible software, preoperative information can be transferred to the operating room and used for:

  • ocular image registration;
  • cyclotorsion compensation;
  • digital surgical guidance;
  • toric IOL positioning;
  • digital support during selected stages of cataract surgery.

Specific functions depend on the installed software version and system configuration.

Recording and image distribution

NGENUITY® supports:

  • 2D and 3D video recording;
  • video playback;
  • simultaneous 2D and 3D streaming to multiple displays;
  • Picture-in-Picture;
  • split-screen processing;
  • recording for teaching and documentation.

Technical specifications

  • Type: digital stereoscopic 3D visualization system for ophthalmic microsurgery.
  • Operating format: heads-up.
  • Intended role: adjunct to a compatible surgical microscope.
  • Camera: stereoscopic digital surgical camera.
  • Sensors: 2 × Full HD.
  • Sensor resolution: 1920 × 1080.
  • Camera frame rate: 60 fps per eye.
  • Processing: high-speed digital image processor.
  • Display technology: OLED.
  • Display size: 55 inches.
  • Display resolution: 4K UHD, 3840 × 2160.
  • Display frame rate: 60 fps per eye.
  • 3D viewing: passive polarized glasses.
  • Depth of field: up to 5× compared with specified analog microscopes under defined Alcon test conditions.
  • Magnification: up to 48% greater compared with specified analog microscopes under defined conditions.
  • Depth resolution: up to 42% greater under corresponding comparison conditions.
  • Illumination: lower illumination settings can be used; Alcon reports up to 4× lower levels under specified conditions.
  • Digital modes: Tissue Detail, Capsule Clarity, MIGS, Blue Boost, Performance Green and others depending on software version.
  • Recording: 2D / 3D.
  • Playback: real-time and recorded material.
  • Additional display options: multiple displays, Picture-in-Picture and split screen.
  • Integration: DATAFUSION™, Alcon Digital Image Guidance and compatible Alcon Vision Suite components.

Benefits

For the surgeon and surgical team

  • heads-up viewing enables the surgeon to work from the primary display rather than continuously leaning toward microscope oculars;
  • the large 3D display provides a shared surgical view for the surgeon and operating room team;
  • up to 5× extended depth of field under specified technical conditions can reduce frequent manual refocusing;
  • digital magnification can be up to 48% greater in the specified comparison with analog microscopes;
  • digital enhancement modes allow color, contrast and detail to be adapted to different stages of surgery;
  • DATAFUSION™ displays compatible surgical platform parameters on the primary screen;
  • Digital Image Guidance can support an integrated cataract surgery workflow;
  • procedures can be recorded in 2D or 3D;
  • the shared view supports teaching and collaborative review.

In studies and surveys referenced by Alcon, surgeons using NGENUITY® were substantially more likely to report reduced discomfort or pain, improved posture and improved overall ergonomic comfort compared with conventional ocular-based microscopy.

For the patient

  • digital visualization may allow lower surgical illumination to be used while maintaining the visualization required by the surgeon;
  • extended depth of field and digital image processing support detailed visualization of small structures;
  • integrated digital guidance can make preoperative information available during surgery;
  • lower light levels may reduce ocular light exposure, although the required illumination is determined by the surgeon for each individual procedure.
FEMTO Z8 NEO Switzerland

FEMTO Z8 NEO (Femtosecond Laser Platform)

FEMTO Z8 NEO The FEMTO Z8 NEO is a mobile, multipurpose femtosecond laser platform for ophthalmic surgery. A single system supports refractive surgery, cataract surgery and therapeutic corneal procedures. The platform is based on a low-energy pulse concept and incorporates intraoperative optical coherence tomography (OCT). Manufacturer Ziemer Ophthalmic Systems AG, Switzerland. Ziemer has developed its low-energy approach to femtosecond laser surgery over several generations of systems. The first FEMTO LDV system became commercially available in 2005. Regulatory status: CE marked; FDA cleared; Availability and regulatory clearance of individual applications may vary by country. Applications Refractive surgery CLEAR / CLEAR Supra: lenticule extraction for flapless vision correction; Z-LASIK / LASIK Supra: corneal flap creation; Creation of intrastromal pockets. Cataract surgery Z-CATARACT / CLARIGS: capsulotomy, lens fragmentation, clear corneal incisions and arcuate incisions. Therapeutic corneal surgery Keratoplasty: penetrating and lamellar techniques, including anterior and posterior procedures; Tunnel creation for intracorneal ring segments (ICRS). Technology and features Low Energy Concept The handpiece is designed to operate with a short working distance between the laser optics and the eye. This allows the laser beam to be focused into a very small spot while using low pulse energy. Small overlapping laser spots enable precise tissue separation and minimize tissue bridges. According to the manufacturer, the low-energy approach also reduces the potential for undesirable mechanical effects such as tissue rupture and gas-bubble formation. Intraoperative OCT Integrated optical coherence tomography provides visualization of ocular structures during the surgical procedure. The system detects the cornea, iris and crystalline lens and assists the surgeon in planning the position and parameters of laser treatments. TopView Imaging provides an additional visualization option during the procedure. SLIM handpiece and patient interface The SLIM handpiece and SLIM patient interface are designed to facilitate docking across a range of ocular anatomies. The system can also be used in pediatric cataract surgery and in patients with limited orbital access. Laser Monitoring System The integrated Laser Monitoring System monitors laser operation and supports consistent performance when the device is used in different operating-room environments during the same day. Mobility and integration The FEMTO Z8 NEO is built as a mobile wheeled platform with a braking system. It can be positioned directly beside the operating table and surgical microscope and moved away after completion of the laser step. The patient does not need to be transferred to another surgical table for the laser portion of the procedure. Additional features include: Automatic calibration at every start-up; Mobility between operating rooms; Plug-and-Play setup; Integration with ablation and excimer laser systems from other manufacturers. Technical specifications Type: ophthalmic femtosecond laser. Operating principle: photodisruption. Wavelength: 1020–1060 nm, near-infrared range. Pulse duration: 200–500 fs according to FDA documentation. Pulse energy: low-energy technology with operating modes in the nanojoule range. Pulse repetition rate: depends on configuration and operating mode. Intraoperative imaging: OCT and TopView Imaging. Configuration: mobile wheeled platform. Benefits For the surgeon and clinic One platform for refractive, cataract and therapeutic corneal surgery; Mobile design for use across different operating rooms; Automatic calibration at start-up; Integrated intraoperative OCT and TopView Imaging; Compatibility with ablation lasers from other manufacturers; Expandable functionality through software applications. For the patient Low-energy laser pulse technology; No need for intraoperative transfer between surgical systems; Patient interface designed to accommodate different ocular anatomies; Platform can also be used in pediatric cataract surgery and in patients with limited orbital access.

Learn more
FEMTO Z8 NEO Switzerland

FEMTO Z8 NEO (Femtosecond Laser Platform)

Manufacturer: Ziemer Ophthalmic Systems AG (Ziemer Group)
Country of manufacture: Switzerland

FEMTO Z8 NEO

The FEMTO Z8 NEO is a mobile, multipurpose femtosecond laser platform for ophthalmic surgery. A single system supports refractive surgery, cataract surgery and therapeutic corneal procedures. The platform is based on a low-energy pulse concept and incorporates intraoperative optical coherence tomography (OCT).

Manufacturer

Ziemer Ophthalmic Systems AG, Switzerland.

Ziemer has developed its low-energy approach to femtosecond laser surgery over several generations of systems. The first FEMTO LDV system became commercially available in 2005.

Regulatory status:

  • CE marked;
  • FDA cleared;
  • Availability and regulatory clearance of individual applications may vary by country.

Applications

Refractive surgery

  • CLEAR / CLEAR Supra: lenticule extraction for flapless vision correction;
  • Z-LASIK / LASIK Supra: corneal flap creation;
  • Creation of intrastromal pockets.

Cataract surgery

  • Z-CATARACT / CLARIGS: capsulotomy, lens fragmentation, clear corneal incisions and arcuate incisions.

Therapeutic corneal surgery

  • Keratoplasty: penetrating and lamellar techniques, including anterior and posterior procedures;
  • Tunnel creation for intracorneal ring segments (ICRS).

Technology and features

Low Energy Concept

The handpiece is designed to operate with a short working distance between the laser optics and the eye. This allows the laser beam to be focused into a very small spot while using low pulse energy.

Small overlapping laser spots enable precise tissue separation and minimize tissue bridges. According to the manufacturer, the low-energy approach also reduces the potential for undesirable mechanical effects such as tissue rupture and gas-bubble formation.

Intraoperative OCT

Integrated optical coherence tomography provides visualization of ocular structures during the surgical procedure. The system detects the cornea, iris and crystalline lens and assists the surgeon in planning the position and parameters of laser treatments.

TopView Imaging provides an additional visualization option during the procedure.

SLIM handpiece and patient interface

The SLIM handpiece and SLIM patient interface are designed to facilitate docking across a range of ocular anatomies. The system can also be used in pediatric cataract surgery and in patients with limited orbital access.

Laser Monitoring System

The integrated Laser Monitoring System monitors laser operation and supports consistent performance when the device is used in different operating-room environments during the same day.

Mobility and integration

The FEMTO Z8 NEO is built as a mobile wheeled platform with a braking system. It can be positioned directly beside the operating table and surgical microscope and moved away after completion of the laser step. The patient does not need to be transferred to another surgical table for the laser portion of the procedure.

Additional features include:

  • Automatic calibration at every start-up;
  • Mobility between operating rooms;
  • Plug-and-Play setup;
  • Integration with ablation and excimer laser systems from other manufacturers.

Technical specifications

  • Type: ophthalmic femtosecond laser.
  • Operating principle: photodisruption.
  • Wavelength: 1020–1060 nm, near-infrared range.
  • Pulse duration: 200–500 fs according to FDA documentation.
  • Pulse energy: low-energy technology with operating modes in the nanojoule range.
  • Pulse repetition rate: depends on configuration and operating mode.
  • Intraoperative imaging: OCT and TopView Imaging.
  • Configuration: mobile wheeled platform.

Benefits

For the surgeon and clinic

  • One platform for refractive, cataract and therapeutic corneal surgery;
  • Mobile design for use across different operating rooms;
  • Automatic calibration at start-up;
  • Integrated intraoperative OCT and TopView Imaging;
  • Compatibility with ablation lasers from other manufacturers;
  • Expandable functionality through software applications.

For the patient

  • Low-energy laser pulse technology;
  • No need for intraoperative transfer between surgical systems;
  • Patient interface designed to accommodate different ocular anatomies;
  • Platform can also be used in pediatric cataract surgery and in patients with limited orbital access.
OCULUS Corvis® ST Germany

OCULUS Corvis® ST Tonometer and Corneal Biomechanics Analyzer

OCULUS Corvis® ST Tonometer and Corneal Biomechanics Analyzer Overview The OCULUS Corvis® ST is a non-contact tonometer and pachymeter equipped with a high-speed Scheimpflug camera for dynamic assessment of the corneal response to a defined air pulse. During measurement, the system records the corneal deformation process and uses these data to determine intraocular pressure, biomechanically corrected intraocular pressure (bIOP), corneal thickness and dynamic corneal response parameters. Depending on the installed software configuration, Corvis® ST also provides tools for biomechanical ectasia screening, post-laser and post-crosslinking follow-up and additional biomechanical assessment in glaucoma. Manufacturer OCULUS Optikgeräte GmbH, Wetzlar, Germany. The OCULUS quality management system is certified according to ISO 13485 and Regulation (EU) 2017/745 on medical devices. Availability of individual software modules and functions varies by system configuration and market. Applications Keratoconus and ectasia screening Corvis® ST records the dynamic response of the cornea to an air pulse and calculates parameters describing its deformation behavior. With the optional Dynamic Corneal Response software, the Corvis Biomechanical Index (CBI) can be calculated. It combines several biomechanical parameters and helps identify corneas with an atypical biomechanical profile. The system can be used: in patients with suspected keratoconus; for ectasia risk assessment before refractive surgery; for longitudinal assessment of corneal biomechanical changes; as an adjunct to corneal topography and tomography. Corvis® ST should not be used in isolation to establish a diagnosis of keratoconus. Its results are interpreted together with clinical examination, topography and corneal tomography. Preoperative assessment before refractive surgery Corvis® ST biomechanical parameters can provide additional information when assessing candidates for laser vision correction, including: LASIK; FemtoLASIK; PRK and TransPRK; SMILE and other lenticule-based procedures. When Corvis® ST is combined with Pentacam®, the Tomographic Biomechanical Index (TBI) integrates biomechanical and tomographic information. TBI uses an artificial intelligence algorithm for combined ectasia risk assessment. A compatible software configuration and Pentacam® data are required for TBI calculation. Glaucoma assessment Corvis® ST measures intraocular pressure and calculates biomechanically corrected IOP (bIOP). The bIOP calculation incorporates: corneal thickness; age; biomechanical corneal response. The resulting bIOP value is less dependent on corneal biomechanical properties and thickness than conventional non-contact IOP measurements. Depending on configuration, optional Glaucoma Screening Software with the Biomechanical Glaucoma Factor (BGF) may also be available. BGF was developed as an additional biomechanical risk indicator for normal-tension glaucoma. Corvis® ST does not replace other clinically required tonometry, visual field testing, optic nerve OCT or optic nerve head assessment. Follow-up after laser vision correction and corneal crosslinking Optional software allows longitudinal comparison of corneal biomechanical parameters. CBI-LVC is designed to assess biomechanical stability after laser vision correction. The BEST Display can: compare examinations against a baseline; analyze changes in biomechanical parameters; display stress-strain curves; superimpose deformation videos; evaluate changes after corneal crosslinking; provide biomechanical keratoconus staging. According to OCULUS, changes in selected biomechanical parameters following crosslinking can be measurable within several weeks after treatment. Technology and features High-speed Scheimpflug camera Corvis® ST incorporates a high-speed Scheimpflug camera operating at 4,330 images per second. During one measurement, the system records: 140 images; within 31 ms after onset of the air pulse; across an 8.5 mm horizontal corneal section. The sequence generates a short video of corneal deformation. The light source is a UV-free 470 nm blue LED. Air pulse During measurement, the cornea is exposed to a controlled air pulse. The instrument automatically tracks eye position and initiates measurement once the required alignment and focus have been achieved. This approach standardizes acquisition conditions and reduces operator influence on the measurement process. Complete deformation cycle The high-speed camera records the principal stages of the corneal response: natural convex shape; first applanation; inward movement; highest concavity; outward movement; second applanation; return toward the natural shape. The image sequence is analyzed to derive Dynamic Corneal Response parameters describing the speed, magnitude and geometry of deformation. Biomechanically corrected IOP (bIOP) bIOP is calculated with consideration of corneal biomechanical response, corneal thickness and patient age. Unlike measurement methods that depend on light reflection from the tear film, the Scheimpflug imaging principle used by Corvis® ST does not depend on tear-film reflection. Together with automatic tracking and auto release, this supports highly repeatable IOP and corneal thickness measurements. Dynamic Corneal Response Optional Dynamic Corneal Response software performs extended analysis of the Scheimpflug image sequence acquired during the air pulse. Depending on the software version, available parameters and tools include: first and second applanation parameters; highest-concavity parameters; Deformation Amplitude Ratio; Integrated Radius; Stiffness Parameter at First Applanation (SP-A1); Ambrósio Relational Thickness; Stress-Strain Index (SSI); Corvis Biomechanical Index (CBI); CBI-LVC; BEST Display; Tomographic Biomechanical Index (TBI) when integrated with Pentacam®. Corvis Biomechanical Index (CBI) CBI is calculated from a combination of dynamic corneal response parameters. The Vinciguerra Screening Report compares the patient's values with normative information and assists the clinician in identifying an atypical biomechanical corneal profile. The index ranges from 0 to 1, with higher values associated with a biomechanical profile more characteristic of ectatic corneas. CBI is a screening parameter and should be interpreted together with other diagnostic findings. Tomographic Biomechanical Index (TBI) TBI combines: Pentacam® tomographic information; Corvis® ST biomechanical measurements. The index is calculated using an artificial intelligence algorithm. Combining geometry and biomechanics provides a more comprehensive approach to ectasia risk assessment and preoperative screening. Automatic TBI calculation requires Corvis® ST and Pentacam® to be connected within a compatible software environment, together with the appropriate Pentacam® software license. Pachymetry Corvis® ST measures corneal thickness during the same examination as tonometry. Key parameters include: pachymetry range of 300–1,200 µm; 8.5 mm horizontal measurement coverage; 576 measurement points per image. The software can display current corneal thickness measurements and pachymetric changes over time. Automatic tracking and quality control The system includes: 3D auto tracking; automatic measurement release; integrated measurement quality assessment. Automation helps standardize eye position and the timing of the air pulse, reducing dependence on operator technique. Patient communication In selected software configurations, IOP and corneal thickness values together with the deformation video can be prepared for transmission to the patient by email. The feature is primarily intended to support clear explanation of examination findings. Technical specifications Type: non-contact tonometer and pachymeter with high-speed Scheimpflug camera. Measurement principle: dynamic recording of corneal deformation following a controlled air pulse. IOP measurement range: 6–60 mmHg. Measurement distance: 11 mm. Internal fixation light: red LED. Positioning: 3D auto tracking. Measurement release: automatic. Scheimpflug camera frame rate: 4,330 images per second. Single measurement recording: 140 images within 31 ms. Horizontal measurement coverage: 8.5 mm. Pachymeter range: 300–1,200 µm. Measuring points: 576 per image. Light source: 470 nm blue LED, UV-free. Standard outputs: IOP, bIOP, corneal thickness, pachymetric progression and biomechanical response video. Dynamic Corneal Response software: optional. CBI, TBI, CBI-LVC, BEST Display and SSI: available with applicable software configurations. TBI: requires integration with Pentacam® tomographic data. Dimensions (W × D × H): 266 × 538 × 495–525 mm. Weight: approximately 14 kg. Maximum power consumption: 26 W. Power supply: 100–240 V AC, 50–60 Hz. Benefits For the clinician and clinic non-contact tonometry, pachymetry and dynamic corneal imaging within one system; 4,330 images per second for analysis of the full deformation cycle; bIOP incorporating corneal biomechanics, corneal thickness and age; Scheimpflug measurement does not depend on tear-film reflection; automatic 3D tracking and auto release; CBI for biomechanical corneal screening; TBI for combined tomographic and biomechanical assessment when integrated with Pentacam®; CBI-LVC and BEST Display for longitudinal assessment following laser vision correction and crosslinking; additional biomechanical information that can contribute to glaucoma assessment. For the patient non-contact examination; no topical anesthetic drops are required; the dynamic deformation recording itself takes 31 ms; one examination provides information about IOP, corneal thickness and biomechanical response; deformation video can be used to explain the examination visually.

Learn more
OCULUS Corvis® ST Germany

OCULUS Corvis® ST Tonometer and Corneal Biomechanics Analyzer

Manufacturer: OCULUS Optikgeräte GmbH
Country of manufacture: Germany

OCULUS Corvis® ST Tonometer and Corneal Biomechanics Analyzer

Overview

The OCULUS Corvis® ST is a non-contact tonometer and pachymeter equipped with a high-speed Scheimpflug camera for dynamic assessment of the corneal response to a defined air pulse.

During measurement, the system records the corneal deformation process and uses these data to determine intraocular pressure, biomechanically corrected intraocular pressure (bIOP), corneal thickness and dynamic corneal response parameters.

Depending on the installed software configuration, Corvis® ST also provides tools for biomechanical ectasia screening, post-laser and post-crosslinking follow-up and additional biomechanical assessment in glaucoma.

Manufacturer

OCULUS Optikgeräte GmbH, Wetzlar, Germany.

The OCULUS quality management system is certified according to ISO 13485 and Regulation (EU) 2017/745 on medical devices.

Availability of individual software modules and functions varies by system configuration and market.

Applications

Keratoconus and ectasia screening

Corvis® ST records the dynamic response of the cornea to an air pulse and calculates parameters describing its deformation behavior.

With the optional Dynamic Corneal Response software, the Corvis Biomechanical Index (CBI) can be calculated. It combines several biomechanical parameters and helps identify corneas with an atypical biomechanical profile.

The system can be used:

  • in patients with suspected keratoconus;
  • for ectasia risk assessment before refractive surgery;
  • for longitudinal assessment of corneal biomechanical changes;
  • as an adjunct to corneal topography and tomography.

Corvis® ST should not be used in isolation to establish a diagnosis of keratoconus. Its results are interpreted together with clinical examination, topography and corneal tomography.

Preoperative assessment before refractive surgery

Corvis® ST biomechanical parameters can provide additional information when assessing candidates for laser vision correction, including:

  • LASIK;
  • FemtoLASIK;
  • PRK and TransPRK;
  • SMILE and other lenticule-based procedures.

When Corvis® ST is combined with Pentacam®, the Tomographic Biomechanical Index (TBI) integrates biomechanical and tomographic information.

TBI uses an artificial intelligence algorithm for combined ectasia risk assessment. A compatible software configuration and Pentacam® data are required for TBI calculation.

Glaucoma assessment

Corvis® ST measures intraocular pressure and calculates biomechanically corrected IOP (bIOP).

The bIOP calculation incorporates:

  • corneal thickness;
  • age;
  • biomechanical corneal response.

The resulting bIOP value is less dependent on corneal biomechanical properties and thickness than conventional non-contact IOP measurements.

Depending on configuration, optional Glaucoma Screening Software with the Biomechanical Glaucoma Factor (BGF) may also be available. BGF was developed as an additional biomechanical risk indicator for normal-tension glaucoma.

Corvis® ST does not replace other clinically required tonometry, visual field testing, optic nerve OCT or optic nerve head assessment.

Follow-up after laser vision correction and corneal crosslinking

Optional software allows longitudinal comparison of corneal biomechanical parameters.

CBI-LVC is designed to assess biomechanical stability after laser vision correction.

The BEST Display can:

  • compare examinations against a baseline;
  • analyze changes in biomechanical parameters;
  • display stress-strain curves;
  • superimpose deformation videos;
  • evaluate changes after corneal crosslinking;
  • provide biomechanical keratoconus staging.

According to OCULUS, changes in selected biomechanical parameters following crosslinking can be measurable within several weeks after treatment.

Technology and features

High-speed Scheimpflug camera

Corvis® ST incorporates a high-speed Scheimpflug camera operating at 4,330 images per second.

During one measurement, the system records:

  • 140 images;
  • within 31 ms after onset of the air pulse;
  • across an 8.5 mm horizontal corneal section.

The sequence generates a short video of corneal deformation. The light source is a UV-free 470 nm blue LED.

Air pulse

During measurement, the cornea is exposed to a controlled air pulse.

The instrument automatically tracks eye position and initiates measurement once the required alignment and focus have been achieved.

This approach standardizes acquisition conditions and reduces operator influence on the measurement process.

Complete deformation cycle

The high-speed camera records the principal stages of the corneal response:

  • natural convex shape;
  • first applanation;
  • inward movement;
  • highest concavity;
  • outward movement;
  • second applanation;
  • return toward the natural shape.

The image sequence is analyzed to derive Dynamic Corneal Response parameters describing the speed, magnitude and geometry of deformation.

Biomechanically corrected IOP (bIOP)

bIOP is calculated with consideration of corneal biomechanical response, corneal thickness and patient age.

Unlike measurement methods that depend on light reflection from the tear film, the Scheimpflug imaging principle used by Corvis® ST does not depend on tear-film reflection.

Together with automatic tracking and auto release, this supports highly repeatable IOP and corneal thickness measurements.

Dynamic Corneal Response

Optional Dynamic Corneal Response software performs extended analysis of the Scheimpflug image sequence acquired during the air pulse.

Depending on the software version, available parameters and tools include:

  • first and second applanation parameters;
  • highest-concavity parameters;
  • Deformation Amplitude Ratio;
  • Integrated Radius;
  • Stiffness Parameter at First Applanation (SP-A1);
  • Ambrósio Relational Thickness;
  • Stress-Strain Index (SSI);
  • Corvis Biomechanical Index (CBI);
  • CBI-LVC;
  • BEST Display;
  • Tomographic Biomechanical Index (TBI) when integrated with Pentacam®.

Corvis Biomechanical Index (CBI)

CBI is calculated from a combination of dynamic corneal response parameters.

The Vinciguerra Screening Report compares the patient's values with normative information and assists the clinician in identifying an atypical biomechanical corneal profile.

The index ranges from 0 to 1, with higher values associated with a biomechanical profile more characteristic of ectatic corneas. CBI is a screening parameter and should be interpreted together with other diagnostic findings.

Tomographic Biomechanical Index (TBI)

TBI combines:

  • Pentacam® tomographic information;
  • Corvis® ST biomechanical measurements.

The index is calculated using an artificial intelligence algorithm.

Combining geometry and biomechanics provides a more comprehensive approach to ectasia risk assessment and preoperative screening.

Automatic TBI calculation requires Corvis® ST and Pentacam® to be connected within a compatible software environment, together with the appropriate Pentacam® software license.

Pachymetry

Corvis® ST measures corneal thickness during the same examination as tonometry.

Key parameters include:

  • pachymetry range of 300–1,200 µm;
  • 8.5 mm horizontal measurement coverage;
  • 576 measurement points per image.

The software can display current corneal thickness measurements and pachymetric changes over time.

Automatic tracking and quality control

The system includes:

  • 3D auto tracking;
  • automatic measurement release;
  • integrated measurement quality assessment.

Automation helps standardize eye position and the timing of the air pulse, reducing dependence on operator technique.

Patient communication

In selected software configurations, IOP and corneal thickness values together with the deformation video can be prepared for transmission to the patient by email.

The feature is primarily intended to support clear explanation of examination findings.

Technical specifications

  • Type: non-contact tonometer and pachymeter with high-speed Scheimpflug camera.
  • Measurement principle: dynamic recording of corneal deformation following a controlled air pulse.
  • IOP measurement range: 6–60 mmHg.
  • Measurement distance: 11 mm.
  • Internal fixation light: red LED.
  • Positioning: 3D auto tracking.
  • Measurement release: automatic.
  • Scheimpflug camera frame rate: 4,330 images per second.
  • Single measurement recording: 140 images within 31 ms.
  • Horizontal measurement coverage: 8.5 mm.
  • Pachymeter range: 300–1,200 µm.
  • Measuring points: 576 per image.
  • Light source: 470 nm blue LED, UV-free.
  • Standard outputs: IOP, bIOP, corneal thickness, pachymetric progression and biomechanical response video.
  • Dynamic Corneal Response software: optional.
  • CBI, TBI, CBI-LVC, BEST Display and SSI: available with applicable software configurations.
  • TBI: requires integration with Pentacam® tomographic data.
  • Dimensions (W × D × H): 266 × 538 × 495–525 mm.
  • Weight: approximately 14 kg.
  • Maximum power consumption: 26 W.
  • Power supply: 100–240 V AC, 50–60 Hz.

Benefits

For the clinician and clinic

  • non-contact tonometry, pachymetry and dynamic corneal imaging within one system;
  • 4,330 images per second for analysis of the full deformation cycle;
  • bIOP incorporating corneal biomechanics, corneal thickness and age;
  • Scheimpflug measurement does not depend on tear-film reflection;
  • automatic 3D tracking and auto release;
  • CBI for biomechanical corneal screening;
  • TBI for combined tomographic and biomechanical assessment when integrated with Pentacam®;
  • CBI-LVC and BEST Display for longitudinal assessment following laser vision correction and crosslinking;
  • additional biomechanical information that can contribute to glaucoma assessment.

For the patient

  • non-contact examination;
  • no topical anesthetic drops are required;
  • the dynamic deformation recording itself takes 31 ms;
  • one examination provides information about IOP, corneal thickness and biomechanical response;
  • deformation video can be used to explain the examination visually.
Pentacam® Germany

OCULUS Pentacam® / Pentacam® HR (Anterior Segment Tomographer)

Pentacam® and Pentacam® HR The Pentacam® and Pentacam® HR are non-contact anterior segment tomography systems based on a rotating Scheimpflug camera. During a single scan, the system acquires a series of optical cross-sectional images and generates a three-dimensional model of the anterior eye segment from the anterior corneal surface to the posterior surface of the crystalline lens. The examination provides data on the anterior and posterior corneal surfaces, corneal thickness and refractive power, as well as parameters of the anterior chamber. The Pentacam® HR provides higher-resolution imaging and a greater density of measurement data. Manufacturer OCULUS Optikgeräte GmbH, Wetzlar, Germany. The OCULUS quality management system is certified: according to ISO 13485; in accordance with Regulation (EU) 2017/745 on medical devices (MDR). Availability of individual software modules and functions depends on the model, year of manufacture, installed software and country of use. Applications Refractive surgery The Pentacam® is used for comprehensive corneal assessment before refractive surgery. Tomography of the anterior and posterior corneal surfaces, pachymetry and analysis of corneal thickness progression support the detection of signs associated with keratoconus and other ectatic disorders and help assess the cornea before LASIK, PRK, SMILE and other procedures. The system is also used for: preoperative planning of corneal refractive surgery; planning of intracorneal ring implantation; comparison of examinations and documentation of corneal changes following surgery. Cataract surgery The Pentacam® provides information on total corneal refractive power, including data from the posterior corneal surface, for cataract surgery planning and IOL selection. The Cataract Pre-OP Display assists in assessing corneal parameters when considering standard, toric, aspheric and multifocal IOLs. Additional options include: IOL Calculator for treated and untreated eyes; Holladay Report and Holladay EKR Detail Report for assessing corneal refractive power after refractive surgery; PNS and 3D Cataract Analysis for quantitative assessment of lens opacities; Total Corneal Refractive Power (TCRP), calculated using ray tracing. The Pentacam® and Pentacam® HR do not measure axial length. When the optional IOL Calculator is used, axial length must be entered separately or obtained from another biometric device. Screening and assessment of corneal pathology The Belin/Ambrósio Enhanced Ectasia Display combines anterior and posterior corneal elevation data with analysis of corneal thickness distribution and progression. It is used to identify tomographic patterns associated with keratoconus and other ectatic disorders and to support risk assessment before refractive surgery. Scheimpflug imaging can also be used to visualize and assess corneal changes associated with conditions including: keratoconus; pellucid marginal degeneration; Fuchs' dystrophy; pterygium; corneal scars and other structural abnormalities. The Belin/Ambrósio Enhanced Ectasia Display was developed with the involvement of Prof. Michael W. Belin and Renato Ambrósio Jr. Anterior chamber assessment in glaucoma screening The Pentacam® automatically determines anterior chamber parameters including: anterior chamber angle; anterior chamber depth; anterior chamber volume; corneal thickness. These measurements can form part of a comprehensive assessment of patients at risk of angle closure. The software also includes various correction tables and formulas for adjusting measured intraocular pressure according to corneal thickness. The Pentacam® does not replace tonometry, perimetry, optic nerve assessment or other components of a complete glaucoma evaluation. Contact lens fitting Optional Pentacam® software assists with fitting rigid gas-permeable, orthokeratology and other contact lenses using the shape of the measured corneal surface. Functions include: automatic lens suggestions; manual modification of lens parameters; simulated fluorescein patterns; assessment of lens position relative to the corneal surface; an integrated contact lens geometry database. Current Pentacam® HR configurations can also provide extended functionality for scleral lens fitting, depending on the device configuration and installed software. Technology and features Rotating Scheimpflug camera During measurement, the camera rotates around the optical axis and captures sequential images of the anterior eye segment from different angles. The software uses these data to generate a three-dimensional model and calculate parameters for the anterior and posterior corneal surfaces. Unlike Placido-based topography, Scheimpflug technology derives elevation information directly from optical cross-sectional images. Central data are measured rather than extrapolated, and the measurement does not depend on reflection from the tear film. The main differences between the two models are: Pentacam®: up to 50 images in 2 seconds and up to 25,000 evaluated elevation points; Pentacam® HR: up to 100 images in 2 seconds in Cornea Fine Scan mode and up to 138,000 evaluated elevation points. Blue LED illumination The system uses blue LEDs with a wavelength of 475 nm and no ultraviolet radiation. Scheimpflug imaging detects light scattering within anterior segment structures, allowing images of the cornea and crystalline lens to be obtained and optical density to be assessed quantitatively when the appropriate software modules are installed. Iris camera A secondary camera is used to monitor eye position during the scan. The software determines: pupil position and shape; horizontal white-to-white corneal diameter (HWTW); eye movements during acquisition. Detected eye movements are taken into account during calculation of the three-dimensional anterior chamber model. Fast Screening Report After image acquisition, the system performs a measurement quality check and summarizes key parameters in a consolidated report. The Fast Screening Report compares examination data with normative values and helps the clinician identify parameters requiring closer assessment. The normative data are based on published clinical studies, and references to the relevant literature can be accessed from within the software. Additional modules Depending on the model and purchased licenses, available modules may include: Belin/Ambrósio Enhanced Ectasia Display; Belin ABCD Keratoconus Staging and Progression Display; Holladay Report and Holladay EKR Detail Report; IOL Calculator; Cataract Pre-OP Display; PNS and 3D Cataract Analysis; Corneal Optical Densitometry; Corneal Rings; corneal aberrometry; 3D pIOL Simulation and Aging Prediction; contact lens fitting software; DICOM. The 3D pIOL Simulation and Aging Prediction module supports preoperative planning of iris-fixated phakic IOLs. Availability depends on the specific Pentacam® model and software configuration. Integration The optional DICOM module enables the Pentacam® to be incorporated into the digital infrastructure of a medical facility. Depending on configuration, the system can: receive patient information through DICOM Worklist; transfer examination results to PACS; provide access to examination data from multiple workstations using the appropriate network licensing. Technical specifications Pentacam® Type: non-contact tomography system with rotating Scheimpflug camera. Camera: digital CCD. Light source: blue LEDs, 475 nm, UV-free. Processor: DSP, 400 million operations per second. Speed: up to 50 images in 2 seconds. Evaluated elevation points: up to 25,000. Curvature range: 3–38 mm / 9–99 D. Precision: ±0.2 D. Reproducibility: ±0.2 D. Operating distance: 80 mm. Dimensions (W × D × H): 275 × 320–400 × 500–530 mm. Measuring head weight: 7.2 kg. Maximum power draw: 35 W. Pentacam® HR Type: non-contact high-resolution tomography system with rotating Scheimpflug camera. Camera: digital CMOS. Light source: blue LEDs, 475 nm, UV-free. Processor: DSP, 400 million operations per second. Speed: up to 100 images in 2 seconds in Cornea Fine Scan mode. Evaluated elevation points: up to 138,000. Curvature range: 3–38 mm / 9–99 D. Precision: ±0.1 D. Reproducibility: ±0.1 D. Operating distance: 80 mm. Dimensions (W × D × H): 275 × 320–400 × 500–530 mm. Measuring head weight: 7.8 kg. Maximum power draw: 35 W. Benefits For the clinician and clinic measurement of both anterior and posterior corneal surfaces with elevation mapping; non-contact pachymetry and three-dimensional anterior segment analysis; measurements do not rely on tear-film reflections as Placido-based topography does; one platform supports refractive, cataract, anterior chamber and contact lens applications; Belin/Ambrósio Enhanced Ectasia Display for comprehensive corneal tomographic analysis; Holladay EKR and other software tools for previously treated and complex corneas; optional integration with DICOM and PACS. For the patient non-contact examination; a standard scan takes approximately 2 seconds; a single examination provides information about both corneal surfaces, corneal thickness and the anterior chamber; tomographic analysis helps the clinician assess the cornea before laser vision correction; visual maps and images can be used to explain examination findings.

Learn more
Pentacam® Germany

OCULUS Pentacam® / Pentacam® HR (Anterior Segment Tomographer)

Manufacturer: OCULUS Optikgeräte GmbH
Country of manufacture: Germany

Pentacam® and Pentacam® HR

The Pentacam® and Pentacam® HR are non-contact anterior segment tomography systems based on a rotating Scheimpflug camera. During a single scan, the system acquires a series of optical cross-sectional images and generates a three-dimensional model of the anterior eye segment from the anterior corneal surface to the posterior surface of the crystalline lens.

The examination provides data on the anterior and posterior corneal surfaces, corneal thickness and refractive power, as well as parameters of the anterior chamber. The Pentacam® HR provides higher-resolution imaging and a greater density of measurement data.

Manufacturer

OCULUS Optikgeräte GmbH, Wetzlar, Germany.

The OCULUS quality management system is certified:

  • according to ISO 13485;
  • in accordance with Regulation (EU) 2017/745 on medical devices (MDR).

Availability of individual software modules and functions depends on the model, year of manufacture, installed software and country of use.

Applications

Refractive surgery

The Pentacam® is used for comprehensive corneal assessment before refractive surgery. Tomography of the anterior and posterior corneal surfaces, pachymetry and analysis of corneal thickness progression support the detection of signs associated with keratoconus and other ectatic disorders and help assess the cornea before LASIK, PRK, SMILE and other procedures.

The system is also used for:

  • preoperative planning of corneal refractive surgery;
  • planning of intracorneal ring implantation;
  • comparison of examinations and documentation of corneal changes following surgery.

Cataract surgery

The Pentacam® provides information on total corneal refractive power, including data from the posterior corneal surface, for cataract surgery planning and IOL selection.

The Cataract Pre-OP Display assists in assessing corneal parameters when considering standard, toric, aspheric and multifocal IOLs.

Additional options include:

  • IOL Calculator for treated and untreated eyes;
  • Holladay Report and Holladay EKR Detail Report for assessing corneal refractive power after refractive surgery;
  • PNS and 3D Cataract Analysis for quantitative assessment of lens opacities;
  • Total Corneal Refractive Power (TCRP), calculated using ray tracing.

The Pentacam® and Pentacam® HR do not measure axial length. When the optional IOL Calculator is used, axial length must be entered separately or obtained from another biometric device.

Screening and assessment of corneal pathology

The Belin/Ambrósio Enhanced Ectasia Display combines anterior and posterior corneal elevation data with analysis of corneal thickness distribution and progression. It is used to identify tomographic patterns associated with keratoconus and other ectatic disorders and to support risk assessment before refractive surgery.

Scheimpflug imaging can also be used to visualize and assess corneal changes associated with conditions including:

  • keratoconus;
  • pellucid marginal degeneration;
  • Fuchs' dystrophy;
  • pterygium;
  • corneal scars and other structural abnormalities.

The Belin/Ambrósio Enhanced Ectasia Display was developed with the involvement of Prof. Michael W. Belin and Renato Ambrósio Jr.

Anterior chamber assessment in glaucoma screening

The Pentacam® automatically determines anterior chamber parameters including:

  • anterior chamber angle;
  • anterior chamber depth;
  • anterior chamber volume;
  • corneal thickness.

These measurements can form part of a comprehensive assessment of patients at risk of angle closure. The software also includes various correction tables and formulas for adjusting measured intraocular pressure according to corneal thickness.

The Pentacam® does not replace tonometry, perimetry, optic nerve assessment or other components of a complete glaucoma evaluation.

Contact lens fitting

Optional Pentacam® software assists with fitting rigid gas-permeable, orthokeratology and other contact lenses using the shape of the measured corneal surface.

Functions include:

  • automatic lens suggestions;
  • manual modification of lens parameters;
  • simulated fluorescein patterns;
  • assessment of lens position relative to the corneal surface;
  • an integrated contact lens geometry database.

Current Pentacam® HR configurations can also provide extended functionality for scleral lens fitting, depending on the device configuration and installed software.

Technology and features

Rotating Scheimpflug camera

During measurement, the camera rotates around the optical axis and captures sequential images of the anterior eye segment from different angles.

The software uses these data to generate a three-dimensional model and calculate parameters for the anterior and posterior corneal surfaces.

Unlike Placido-based topography, Scheimpflug technology derives elevation information directly from optical cross-sectional images. Central data are measured rather than extrapolated, and the measurement does not depend on reflection from the tear film.

The main differences between the two models are:

  • Pentacam®: up to 50 images in 2 seconds and up to 25,000 evaluated elevation points;
  • Pentacam® HR: up to 100 images in 2 seconds in Cornea Fine Scan mode and up to 138,000 evaluated elevation points.

Blue LED illumination

The system uses blue LEDs with a wavelength of 475 nm and no ultraviolet radiation.

Scheimpflug imaging detects light scattering within anterior segment structures, allowing images of the cornea and crystalline lens to be obtained and optical density to be assessed quantitatively when the appropriate software modules are installed.

Iris camera

A secondary camera is used to monitor eye position during the scan.

The software determines:

  • pupil position and shape;
  • horizontal white-to-white corneal diameter (HWTW);
  • eye movements during acquisition.

Detected eye movements are taken into account during calculation of the three-dimensional anterior chamber model.

Fast Screening Report

After image acquisition, the system performs a measurement quality check and summarizes key parameters in a consolidated report.

The Fast Screening Report compares examination data with normative values and helps the clinician identify parameters requiring closer assessment.

The normative data are based on published clinical studies, and references to the relevant literature can be accessed from within the software.

Additional modules

Depending on the model and purchased licenses, available modules may include:

  • Belin/Ambrósio Enhanced Ectasia Display;
  • Belin ABCD Keratoconus Staging and Progression Display;
  • Holladay Report and Holladay EKR Detail Report;
  • IOL Calculator;
  • Cataract Pre-OP Display;
  • PNS and 3D Cataract Analysis;
  • Corneal Optical Densitometry;
  • Corneal Rings;
  • corneal aberrometry;
  • 3D pIOL Simulation and Aging Prediction;
  • contact lens fitting software;
  • DICOM.

The 3D pIOL Simulation and Aging Prediction module supports preoperative planning of iris-fixated phakic IOLs. Availability depends on the specific Pentacam® model and software configuration.

Integration

The optional DICOM module enables the Pentacam® to be incorporated into the digital infrastructure of a medical facility.

Depending on configuration, the system can:

  • receive patient information through DICOM Worklist;
  • transfer examination results to PACS;
  • provide access to examination data from multiple workstations using the appropriate network licensing.

Technical specifications

Pentacam®

  • Type: non-contact tomography system with rotating Scheimpflug camera.
  • Camera: digital CCD.
  • Light source: blue LEDs, 475 nm, UV-free.
  • Processor: DSP, 400 million operations per second.
  • Speed: up to 50 images in 2 seconds.
  • Evaluated elevation points: up to 25,000.
  • Curvature range: 3–38 mm / 9–99 D.
  • Precision: ±0.2 D.
  • Reproducibility: ±0.2 D.
  • Operating distance: 80 mm.
  • Dimensions (W × D × H): 275 × 320–400 × 500–530 mm.
  • Measuring head weight: 7.2 kg.
  • Maximum power draw: 35 W.

Pentacam® HR

  • Type: non-contact high-resolution tomography system with rotating Scheimpflug camera.
  • Camera: digital CMOS.
  • Light source: blue LEDs, 475 nm, UV-free.
  • Processor: DSP, 400 million operations per second.
  • Speed: up to 100 images in 2 seconds in Cornea Fine Scan mode.
  • Evaluated elevation points: up to 138,000.
  • Curvature range: 3–38 mm / 9–99 D.
  • Precision: ±0.1 D.
  • Reproducibility: ±0.1 D.
  • Operating distance: 80 mm.
  • Dimensions (W × D × H): 275 × 320–400 × 500–530 mm.
  • Measuring head weight: 7.8 kg.
  • Maximum power draw: 35 W.

Benefits

For the clinician and clinic

  • measurement of both anterior and posterior corneal surfaces with elevation mapping;
  • non-contact pachymetry and three-dimensional anterior segment analysis;
  • measurements do not rely on tear-film reflections as Placido-based topography does;
  • one platform supports refractive, cataract, anterior chamber and contact lens applications;
  • Belin/Ambrósio Enhanced Ectasia Display for comprehensive corneal tomographic analysis;
  • Holladay EKR and other software tools for previously treated and complex corneas;
  • optional integration with DICOM and PACS.

For the patient

  • non-contact examination;
  • a standard scan takes approximately 2 seconds;
  • a single examination provides information about both corneal surfaces, corneal thickness and the anterior chamber;
  • tomographic analysis helps the clinician assess the cornea before laser vision correction;
  • visual maps and images can be used to explain examination findings.
Optovue SOLIX France

Optovue SOLIX Optical Coherence Tomographer

Optovue SOLIX Optical Coherence Tomographer Overview The Optovue SOLIX is a spectral-domain optical coherence tomography (SD-OCT) system with OCT angiography and an integrated color fundus camera. Its FullRange® platform is designed for anterior and posterior segment imaging and operates at a scan speed of 120,000 A-scans per second. The system combines structural OCT imaging, OCT angiography, fundus photography and anterior segment assessment within a single diagnostic platform. Manufacturer Optovue, a Visionix brand. Regulatory status: SOLIX has FDA 510(k) clearance K222166; AngioVue® is indicated as an aid in visualization of retinal and choroidal vascular structures; AngioAnalytics™ provides quantitative measurement of vessel density, foveal avascular zone, retinal and nerve fiber layer thickness and optic disc parameters; the integrated reference database is used to compare selected structural OCT measurements of the retina, RNFL and optic disc against a database of known normal subjects; the FDA-cleared configuration does not include a separate OCT-A normative database. Applications Retina and macula SOLIX provides imaging of the retina, vitreous and choroid. FullRange imaging increases scan width and depth and can be useful when examining highly myopic eyes. Available retinal tools include: structural retinal OCT; retinal thickness mapping; En Face OCT; FullRange Retina; iWellness; AngioWellness; AngioVue® OCT-A; 3D vascular rendering. AngioWellness combines structural retinal and ganglion cell information with vascular metrics and can support comprehensive assessment of patients with retinal vascular abnormalities or suspected glaucoma. Glaucoma The SOLIX glaucoma package combines structural assessment of the optic nerve head, retinal nerve fiber layer and ganglion cell complex with vascular analysis. The system provides: RNFL thickness measurements; GCC analysis; optic nerve head parameters; radial peripapillary capillary density maps; comparison of structural measurements against a reference database; longitudinal RNFL and GCC trend analysis. Scanning with SSADA and Motion Correction Technology can generate structural OCT and OCT-A information with AngioAnalytics™ metrics. DualTrac™, Motion Correction Technology, SSADA, projection artifact reduction and automated segmentation are used to improve measurement stability and subsequent analysis. Anterior segment FullRange® imaging allows examination of the anterior chamber from the anterior corneal surface to the anterior surface of the crystalline lens. Selected scan modes can also image the entire crystalline lens. Angle Scan with a four-up display enables visualization and quantitative assessment of anterior chamber angle structures. The 10 mm Corneal Layer Map provides: epithelial thickness; stromal thickness; total corneal thickness; change analysis between examinations. These measurements can support corneal assessment before refractive procedures and follow-up of patients with keratoconus and ocular surface disorders. Topography and aberrometry An optional OCT topography module is available for SOLIX. Depending on configuration, it provides: axial maps; tangential maps; elevation maps; anterior and posterior corneal surface data; pachymetry; epithelial thickness mapping; Zernike coefficients; lower-order and higher-order aberration data; visual acuity simulation. Up to six selected maps can be displayed simultaneously. These measurements can support assessment before refractive and cataract surgery, phakic IOL planning and specialty contact lens fitting. Fundus camera SOLIX incorporates a non-contact color fundus camera. Features include: color fundus photography; 5 MP resolution; 45° field of view; 35° small-pupil mode; pseudo red-free display; external color photography; external infrared imaging. Infrared imaging can be used to visualize external ocular structures including the upper and lower eyelids. Technology and features 120,000 A-scans per second SOLIX operates at up to 120,000 A-scans per second. The high acquisition rate supports dense volumetric data sets for anterior and posterior segment imaging while reducing acquisition time. Combined with motion correction and multi-volume averaging, the higher scan rate supports stable, detailed diagnostic imaging. FullRange® FullRange® extends OCT scan width and depth. Key parameters include: posterior segment: scan width up to 16 mm and depth up to 6.25 mm; anterior segment: scan length up to 18 mm and depth up to 6.25 mm. FullRange Retina provides extended visualization of posterior structures including the vitreous, retina and choroid. FullRange Anterior provides a wide view of the anterior chamber in a single scan. AngioVue® OCT-A and AngioAnalytics™ AngioVue® provides non-contact OCT angiography without intravenous contrast injection. The system visualizes retinal and choroidal microvasculature and provides quantitative AngioAnalytics™ measurements. Depending on the protocol, measurements include: vessel density; foveal avascular zone; retinal layer thickness; retinal nerve fiber layer thickness; optic disc parameters. Available single OCT-A retinal scan sizes include: 3 × 3 mm; 6.4 × 6.4 mm; 9 × 9 mm; 12 × 12 mm. AngioVue QuadMontage combines four 9 × 9 mm scans to generate a widefield montage of approximately 16 × 16 mm. DualTrac™ Motion Correction Technology DualTrac™ combines eye tracking during image acquisition with software-based post-processing. Motion Correction Technology registers volumes acquired in different directions to reduce motion-related artifacts. This is particularly relevant to volumetric OCT and OCT-A imaging, where motion can affect vascular geometry and quantitative measurements. Data processing SOLIX incorporates several OCT and OCT-A processing technologies. Depending on the protocol, these include: SSADA; Motion Correction Technology; DualTrac™; 3D PAR 2.0 projection artifact reduction; multi-volume averaging; automated segmentation; pixel-by-pixel deviation mapping; 3D vascular rendering. These tools support structured analysis of the retina, optic nerve head and retinal vasculature. Technical specifications Type: spectral-domain optical coherence tomography system with OCT angiography. Scan speed: 120,000 A-scans per second, 120 kHz. Axial resolution: 5 µm in tissue. Transverse resolution: 15 µm in tissue. OCT light source: superluminescent diode, approximately 840 nm. Posterior FullRange: scan width up to 16 mm and depth up to 6.25 mm. Anterior FullRange: scan length up to 18 mm and depth up to 6.25 mm. OCT-A: single scans up to 12 × 12 mm. AngioVue QuadMontage: four 9 × 9 mm scans producing a widefield montage of approximately 16 × 16 mm. Corneal map: 10 mm, 16 meridians. Fundus camera: integrated, non-contact color camera. Fundus camera resolution: 5 MP. Fundus camera field of view: 45°, 35° in small-pupil mode. External imaging: color and infrared, 940 nm. Instrument dimensions (W × D × H): 1072 × 600 × 610 mm. Table dimensions (W × D × H): 952 × 600 × 913 mm. System weight: 95 kg. DICOM: Modality Worklist and Storage. Benefits For the clinician and clinic structural OCT, OCT angiography, anterior segment imaging and fundus photography within one system; 120 kHz scan speed; FullRange anterior and posterior segment imaging; a single protocol can combine structural and vascular data; AngioAnalytics™ provides quantitative vascular metrics; structural RNFL, retinal and optic disc measurements can be compared with a reference database and monitored over time; 10 mm epithelial, stromal and total corneal thickness mapping; optional OCT topography and corneal aberrometry; integrated color fundus photography and external infrared imaging. For the patient OCT and OCT-A examinations are non-contact; OCT angiography does not require intravenous dye injection; high scan speed reduces image acquisition time; multiple structural and vascular diagnostic data sets can be obtained during the same visit; color photographs, maps and 3D images can help the clinician explain examination findings.

Learn more
Optovue SOLIX France

Optovue SOLIX Optical Coherence Tomographer

Manufacturer: Optovue
Country of manufacture: France

Optovue SOLIX Optical Coherence Tomographer

Overview

The Optovue SOLIX is a spectral-domain optical coherence tomography (SD-OCT) system with OCT angiography and an integrated color fundus camera. Its FullRange® platform is designed for anterior and posterior segment imaging and operates at a scan speed of 120,000 A-scans per second.

The system combines structural OCT imaging, OCT angiography, fundus photography and anterior segment assessment within a single diagnostic platform.

Manufacturer

Optovue, a Visionix brand.

Regulatory status:

  • SOLIX has FDA 510(k) clearance K222166;
  • AngioVue® is indicated as an aid in visualization of retinal and choroidal vascular structures;
  • AngioAnalytics™ provides quantitative measurement of vessel density, foveal avascular zone, retinal and nerve fiber layer thickness and optic disc parameters;
  • the integrated reference database is used to compare selected structural OCT measurements of the retina, RNFL and optic disc against a database of known normal subjects;
  • the FDA-cleared configuration does not include a separate OCT-A normative database.

Applications

Retina and macula

SOLIX provides imaging of the retina, vitreous and choroid. FullRange imaging increases scan width and depth and can be useful when examining highly myopic eyes.

Available retinal tools include:

  • structural retinal OCT;
  • retinal thickness mapping;
  • En Face OCT;
  • FullRange Retina;
  • iWellness;
  • AngioWellness;
  • AngioVue® OCT-A;
  • 3D vascular rendering.

AngioWellness combines structural retinal and ganglion cell information with vascular metrics and can support comprehensive assessment of patients with retinal vascular abnormalities or suspected glaucoma.

Glaucoma

The SOLIX glaucoma package combines structural assessment of the optic nerve head, retinal nerve fiber layer and ganglion cell complex with vascular analysis.

The system provides:

  • RNFL thickness measurements;
  • GCC analysis;
  • optic nerve head parameters;
  • radial peripapillary capillary density maps;
  • comparison of structural measurements against a reference database;
  • longitudinal RNFL and GCC trend analysis.

Scanning with SSADA and Motion Correction Technology can generate structural OCT and OCT-A information with AngioAnalytics™ metrics.

DualTrac™, Motion Correction Technology, SSADA, projection artifact reduction and automated segmentation are used to improve measurement stability and subsequent analysis.

Anterior segment

FullRange® imaging allows examination of the anterior chamber from the anterior corneal surface to the anterior surface of the crystalline lens. Selected scan modes can also image the entire crystalline lens.

Angle Scan with a four-up display enables visualization and quantitative assessment of anterior chamber angle structures.

The 10 mm Corneal Layer Map provides:

  • epithelial thickness;
  • stromal thickness;
  • total corneal thickness;
  • change analysis between examinations.

These measurements can support corneal assessment before refractive procedures and follow-up of patients with keratoconus and ocular surface disorders.

Topography and aberrometry

An optional OCT topography module is available for SOLIX.

Depending on configuration, it provides:

  • axial maps;
  • tangential maps;
  • elevation maps;
  • anterior and posterior corneal surface data;
  • pachymetry;
  • epithelial thickness mapping;
  • Zernike coefficients;
  • lower-order and higher-order aberration data;
  • visual acuity simulation.

Up to six selected maps can be displayed simultaneously.

These measurements can support assessment before refractive and cataract surgery, phakic IOL planning and specialty contact lens fitting.

Fundus camera

SOLIX incorporates a non-contact color fundus camera.

Features include:

  • color fundus photography;
  • 5 MP resolution;
  • 45° field of view;
  • 35° small-pupil mode;
  • pseudo red-free display;
  • external color photography;
  • external infrared imaging.

Infrared imaging can be used to visualize external ocular structures including the upper and lower eyelids.

Technology and features

120,000 A-scans per second

SOLIX operates at up to 120,000 A-scans per second.

The high acquisition rate supports dense volumetric data sets for anterior and posterior segment imaging while reducing acquisition time.

Combined with motion correction and multi-volume averaging, the higher scan rate supports stable, detailed diagnostic imaging.

FullRange®

FullRange® extends OCT scan width and depth.

Key parameters include:

  • posterior segment: scan width up to 16 mm and depth up to 6.25 mm;
  • anterior segment: scan length up to 18 mm and depth up to 6.25 mm.

FullRange Retina provides extended visualization of posterior structures including the vitreous, retina and choroid.

FullRange Anterior provides a wide view of the anterior chamber in a single scan.

AngioVue® OCT-A and AngioAnalytics™

AngioVue® provides non-contact OCT angiography without intravenous contrast injection.

The system visualizes retinal and choroidal microvasculature and provides quantitative AngioAnalytics™ measurements.

Depending on the protocol, measurements include:

  • vessel density;
  • foveal avascular zone;
  • retinal layer thickness;
  • retinal nerve fiber layer thickness;
  • optic disc parameters.

Available single OCT-A retinal scan sizes include:

  • 3 × 3 mm;
  • 6.4 × 6.4 mm;
  • 9 × 9 mm;
  • 12 × 12 mm.

AngioVue QuadMontage combines four 9 × 9 mm scans to generate a widefield montage of approximately 16 × 16 mm.

DualTrac™ Motion Correction Technology

DualTrac™ combines eye tracking during image acquisition with software-based post-processing.

Motion Correction Technology registers volumes acquired in different directions to reduce motion-related artifacts.

This is particularly relevant to volumetric OCT and OCT-A imaging, where motion can affect vascular geometry and quantitative measurements.

Data processing

SOLIX incorporates several OCT and OCT-A processing technologies.

Depending on the protocol, these include:

  • SSADA;
  • Motion Correction Technology;
  • DualTrac™;
  • 3D PAR 2.0 projection artifact reduction;
  • multi-volume averaging;
  • automated segmentation;
  • pixel-by-pixel deviation mapping;
  • 3D vascular rendering.

These tools support structured analysis of the retina, optic nerve head and retinal vasculature.

Technical specifications

  • Type: spectral-domain optical coherence tomography system with OCT angiography.
  • Scan speed: 120,000 A-scans per second, 120 kHz.
  • Axial resolution: 5 µm in tissue.
  • Transverse resolution: 15 µm in tissue.
  • OCT light source: superluminescent diode, approximately 840 nm.
  • Posterior FullRange: scan width up to 16 mm and depth up to 6.25 mm.
  • Anterior FullRange: scan length up to 18 mm and depth up to 6.25 mm.
  • OCT-A: single scans up to 12 × 12 mm.
  • AngioVue QuadMontage: four 9 × 9 mm scans producing a widefield montage of approximately 16 × 16 mm.
  • Corneal map: 10 mm, 16 meridians.
  • Fundus camera: integrated, non-contact color camera.
  • Fundus camera resolution: 5 MP.
  • Fundus camera field of view: 45°, 35° in small-pupil mode.
  • External imaging: color and infrared, 940 nm.
  • Instrument dimensions (W × D × H): 1072 × 600 × 610 mm.
  • Table dimensions (W × D × H): 952 × 600 × 913 mm.
  • System weight: 95 kg.
  • DICOM: Modality Worklist and Storage.

Benefits

For the clinician and clinic

  • structural OCT, OCT angiography, anterior segment imaging and fundus photography within one system;
  • 120 kHz scan speed;
  • FullRange anterior and posterior segment imaging;
  • a single protocol can combine structural and vascular data;
  • AngioAnalytics™ provides quantitative vascular metrics;
  • structural RNFL, retinal and optic disc measurements can be compared with a reference database and monitored over time;
  • 10 mm epithelial, stromal and total corneal thickness mapping;
  • optional OCT topography and corneal aberrometry;
  • integrated color fundus photography and external infrared imaging.

For the patient

  • OCT and OCT-A examinations are non-contact;
  • OCT angiography does not require intravenous dye injection;
  • high scan speed reduces image acquisition time;
  • multiple structural and vascular diagnostic data sets can be obtained during the same visit;
  • color photographs, maps and 3D images can help the clinician explain examination findings.
ZEISS IOLMaster® 700 Germany

ZEISS IOLMaster® 700 Optical Biometer

ZEISS IOLMaster® 700 — optical biometry and IOL power calculation The ZEISS IOLMaster® 700 is a non-contact optical biometer based on Swept Source OCT technology. It measures key anatomical parameters of the eye, produces longitudinal OCT images extending from the cornea to the retina, and performs intraocular lens (IOL) power calculations. The technology allows clinicians to obtain numerical biometric measurements and visually verify the anatomical structures on which those measurements are based. Manufacturer: Carl Zeiss Meditec AG, Jena, Germany. Regulatory status and availability CE marked in accordance with applicable European requirements. FDA 510(k) cleared in the United States. Availability of individual functions, formulas, and software modules varies by country and system configuration. Cataract surgery and IOL calculation The ZEISS IOLMaster® 700 is used for preoperative biometry and IOL power calculation in cataract surgery. The system supports a broad range of formulas, including: Barrett Universal II; Barrett TK Universal II with Total Keratometry; Barrett Toric; Barrett TK Toric with Total Keratometry; Haigis; Haigis-T; Hoffer Q; Holladay 1; Holladay 2; SRK/T. Specialized formulas are also available for selected eyes that have previously undergone corneal refractive surgery. Integrated toric IOL calculation tools allow biometric and keratometric information to be used directly within the system without requiring all measurements to be manually transferred to external calculators. ZEISS provides optimized IOL constants for more than 300 lens models, based on data from more than 50,000 cataract procedures. Eyes after refractive surgery Changes in corneal geometry following LASIK, PRK, or LASEK can make IOL power calculation more challenging because standard keratometric assumptions may become less reliable. Dedicated tools include: Haigis-L; Barrett True K; Barrett True K with TK; Total Keratometry with compatible formulas. Barrett True K with TK incorporates Total Keratometry measurements, including direct assessment of the posterior corneal surface. In a published study of post-myopic LASIK eyes, Barrett True K with TK increased the proportion of outcomes within ±0.50 D by more than 12 percentage points compared with Barrett True K using conventional keratometry. For eyes following SMILE, formula selection should follow the current instructions for use and the individual clinical situation. Current ZEISS documentation does not recommend automatically applying standard post-refractive formulas intended for LASIK, LASEK, and PRK to post-ReLEx SMILE eyes. Swept Source OCT and anatomical visualization The IOLMaster® 700 uses Swept Source OCT with a central wavelength of approximately 1055 nm and a scan speed of approximately 2,000 A-scans per second. Images are acquired along six meridians: 0°; 30°; 60°; 90°; 120°; 150°. The Cornea-to-Retina Scan provides longitudinal visualization from the cornea to the retina. OCT images display anatomical structures together with measurement boundaries, allowing the operator to assess measurement plausibility. This helps clinicians: verify biometric measurements; identify unusual ocular geometry; assess crystalline lens position and possible tilt; evaluate patient fixation. According to ZEISS, the technology achieves cataract penetration of up to 99%, reducing the number of cases requiring ultrasound axial-length measurement. Total Keratometry (TK®) Total Keratometry combines: telecentric keratometry of the anterior corneal surface; Swept Source OCT measurement of the posterior corneal surface; corneal thickness information. The system calculates total keratometry using the individual geometry of both corneal surfaces rather than relying only on a model-based relationship between them. Dedicated TK formulas include: Barrett TK Universal II; Barrett TK Toric; Barrett True K with TK. TK measurements can also be used with a number of conventional IOL calculation formulas in accordance with the software instructions for use. Telecentric keratometry The anterior corneal surface is measured using reflections from 18 LED points arranged across three measurement zones. The telecentric principle reduces dependence on the working distance between the instrument and the eye and supports repeatable keratometric measurements. Fixation check OCT imaging of the central macular region helps verify the patient’s direction of gaze during biometry. Visualization of the foveal pit allows the operator to assess whether appropriate fixation was maintained. If fixation is questionable, the measurement can be repeated before the data are accepted for IOL calculation. Central Topography Central Topography provides information about central corneal shape as part of the standard biometry workflow, without requiring a separate diagnostic device or an additional measurement. Central Topography does not replace comprehensive dedicated corneal topography or tomography when clinically indicated. Haigis Suite The Haigis Suite combines formulas from the Haigis family. Depending on the clinical situation and installed software version, these include: Haigis: conventional IOL calculation. Haigis-L: selected eyes after LASIK, LASEK, or PRK. Haigis-T: toric IOL calculation. Additional variants according to the current software version and instructions for use. Integration into the operating room During biometry, the IOLMaster® 700 can acquire a reference image for the ZEISS markerless cataract surgery workflow. The reference image and keratometry measurements can be transferred to ZEISS CALLISTO eye and matched with the live surgical image, including during toric IOL alignment. Integration with ZEISS VERACITY Surgery Planner enables transfer of: an OCT image for assessment of anatomy and possible abnormalities; a reference image for intraoperative guidance; posterior corneal data for Total Keratometry; keratometric and other biometric parameters. Depending on configuration, compatible systems include ZEISS VERACITY Surgery Planner, ZEISS FORUM, ZEISS CALLISTO eye, ZEISS EQ Workplace, and other supported components. Key technical specifications Type: non-contact optical biometer based on Swept Source OCT. OCT central wavelength: approximately 1055 nm. OCT scan speed: approximately 2,000 A-scans per second. OCT acquisition pattern: six meridians at 30° intervals. Axial length measurement range: 14–38 mm. Corneal radius range: 5–11 mm. Anterior chamber depth: 0.7–8 mm. Lens thickness in phakic eyes: 1–10 mm. Artificial lens thickness in pseudophakic eyes: 0.13–2.5 mm. Central corneal thickness: 0.2–1.2 mm. White-to-white: 8–16 mm. Keratometry: telecentric, three-zone measurement using reflections from 18 LED points. Total Keratometry: anterior and posterior corneal surface measurement incorporating central corneal thickness. Measurement method: non-contact. For the surgeon and clinic Key biometric measurements on a single platform. Visual verification of ocular anatomy and measurement boundaries on OCT images. Individual posterior corneal surface measurement with Total Keratometry. Integrated Barrett and Haigis formulas for different clinical requirements. Toric IOL calculation tools. Fixation verification using central macular imaging. Central Topography within the standard biometry workflow. Reference-image acquisition for markerless toric IOL alignment with CALLISTO eye. Digital data transfer within the ZEISS ecosystem. Access to optimized constants for more than 300 IOL models. For the patient Non-contact examination. No topical anesthetic drops required for standard optical biometry. Both eyes can be measured in less than 45 seconds. Swept Source OCT enables optical biometry through many dense cataracts that may be difficult to measure with previous-generation optical biometers. Most parameters required for IOL calculation can be acquired within a single diagnostic workflow.

Learn more
ZEISS IOLMaster® 700 Germany

ZEISS IOLMaster® 700 Optical Biometer

Manufacturer: Carl Zeiss
Country of manufacture: Germany

ZEISS IOLMaster® 700 — optical biometry and IOL power calculation

The ZEISS IOLMaster® 700 is a non-contact optical biometer based on Swept Source OCT technology. It measures key anatomical parameters of the eye, produces longitudinal OCT images extending from the cornea to the retina, and performs intraocular lens (IOL) power calculations.

The technology allows clinicians to obtain numerical biometric measurements and visually verify the anatomical structures on which those measurements are based.

Manufacturer: Carl Zeiss Meditec AG, Jena, Germany.

Regulatory status and availability

  • CE marked in accordance with applicable European requirements.
  • FDA 510(k) cleared in the United States.
  • Availability of individual functions, formulas, and software modules varies by country and system configuration.

Cataract surgery and IOL calculation

The ZEISS IOLMaster® 700 is used for preoperative biometry and IOL power calculation in cataract surgery.

The system supports a broad range of formulas, including:

  • Barrett Universal II;
  • Barrett TK Universal II with Total Keratometry;
  • Barrett Toric;
  • Barrett TK Toric with Total Keratometry;
  • Haigis;
  • Haigis-T;
  • Hoffer Q;
  • Holladay 1;
  • Holladay 2;
  • SRK/T.

Specialized formulas are also available for selected eyes that have previously undergone corneal refractive surgery.

Integrated toric IOL calculation tools allow biometric and keratometric information to be used directly within the system without requiring all measurements to be manually transferred to external calculators.

ZEISS provides optimized IOL constants for more than 300 lens models, based on data from more than 50,000 cataract procedures.

Eyes after refractive surgery

Changes in corneal geometry following LASIK, PRK, or LASEK can make IOL power calculation more challenging because standard keratometric assumptions may become less reliable.

Dedicated tools include:

  • Haigis-L;
  • Barrett True K;
  • Barrett True K with TK;
  • Total Keratometry with compatible formulas.

Barrett True K with TK incorporates Total Keratometry measurements, including direct assessment of the posterior corneal surface.

In a published study of post-myopic LASIK eyes, Barrett True K with TK increased the proportion of outcomes within ±0.50 D by more than 12 percentage points compared with Barrett True K using conventional keratometry.

For eyes following SMILE, formula selection should follow the current instructions for use and the individual clinical situation. Current ZEISS documentation does not recommend automatically applying standard post-refractive formulas intended for LASIK, LASEK, and PRK to post-ReLEx SMILE eyes.

Swept Source OCT and anatomical visualization

The IOLMaster® 700 uses Swept Source OCT with a central wavelength of approximately 1055 nm and a scan speed of approximately 2,000 A-scans per second.

Images are acquired along six meridians:

  • 0°;
  • 30°;
  • 60°;
  • 90°;
  • 120°;
  • 150°.

The Cornea-to-Retina Scan provides longitudinal visualization from the cornea to the retina. OCT images display anatomical structures together with measurement boundaries, allowing the operator to assess measurement plausibility.

This helps clinicians:

  • verify biometric measurements;
  • identify unusual ocular geometry;
  • assess crystalline lens position and possible tilt;
  • evaluate patient fixation.

According to ZEISS, the technology achieves cataract penetration of up to 99%, reducing the number of cases requiring ultrasound axial-length measurement.

Total Keratometry (TK®)

Total Keratometry combines:

  • telecentric keratometry of the anterior corneal surface;
  • Swept Source OCT measurement of the posterior corneal surface;
  • corneal thickness information.

The system calculates total keratometry using the individual geometry of both corneal surfaces rather than relying only on a model-based relationship between them.

Dedicated TK formulas include:

  • Barrett TK Universal II;
  • Barrett TK Toric;
  • Barrett True K with TK.

TK measurements can also be used with a number of conventional IOL calculation formulas in accordance with the software instructions for use.

Telecentric keratometry

The anterior corneal surface is measured using reflections from 18 LED points arranged across three measurement zones.

The telecentric principle reduces dependence on the working distance between the instrument and the eye and supports repeatable keratometric measurements.

Fixation check

OCT imaging of the central macular region helps verify the patient’s direction of gaze during biometry.

Visualization of the foveal pit allows the operator to assess whether appropriate fixation was maintained. If fixation is questionable, the measurement can be repeated before the data are accepted for IOL calculation.

Central Topography

Central Topography provides information about central corneal shape as part of the standard biometry workflow, without requiring a separate diagnostic device or an additional measurement.

Central Topography does not replace comprehensive dedicated corneal topography or tomography when clinically indicated.

Haigis Suite

The Haigis Suite combines formulas from the Haigis family. Depending on the clinical situation and installed software version, these include:

  • Haigis: conventional IOL calculation.
  • Haigis-L: selected eyes after LASIK, LASEK, or PRK.
  • Haigis-T: toric IOL calculation.
  • Additional variants according to the current software version and instructions for use.

Integration into the operating room

During biometry, the IOLMaster® 700 can acquire a reference image for the ZEISS markerless cataract surgery workflow.

The reference image and keratometry measurements can be transferred to ZEISS CALLISTO eye and matched with the live surgical image, including during toric IOL alignment.

Integration with ZEISS VERACITY Surgery Planner enables transfer of:

  • an OCT image for assessment of anatomy and possible abnormalities;
  • a reference image for intraoperative guidance;
  • posterior corneal data for Total Keratometry;
  • keratometric and other biometric parameters.

Depending on configuration, compatible systems include ZEISS VERACITY Surgery Planner, ZEISS FORUM, ZEISS CALLISTO eye, ZEISS EQ Workplace, and other supported components.

Key technical specifications

  • Type: non-contact optical biometer based on Swept Source OCT.
  • OCT central wavelength: approximately 1055 nm.
  • OCT scan speed: approximately 2,000 A-scans per second.
  • OCT acquisition pattern: six meridians at 30° intervals.
  • Axial length measurement range: 14–38 mm.
  • Corneal radius range: 5–11 mm.
  • Anterior chamber depth: 0.7–8 mm.
  • Lens thickness in phakic eyes: 1–10 mm.
  • Artificial lens thickness in pseudophakic eyes: 0.13–2.5 mm.
  • Central corneal thickness: 0.2–1.2 mm.
  • White-to-white: 8–16 mm.
  • Keratometry: telecentric, three-zone measurement using reflections from 18 LED points.
  • Total Keratometry: anterior and posterior corneal surface measurement incorporating central corneal thickness.
  • Measurement method: non-contact.

For the surgeon and clinic

  • Key biometric measurements on a single platform.
  • Visual verification of ocular anatomy and measurement boundaries on OCT images.
  • Individual posterior corneal surface measurement with Total Keratometry.
  • Integrated Barrett and Haigis formulas for different clinical requirements.
  • Toric IOL calculation tools.
  • Fixation verification using central macular imaging.
  • Central Topography within the standard biometry workflow.
  • Reference-image acquisition for markerless toric IOL alignment with CALLISTO eye.
  • Digital data transfer within the ZEISS ecosystem.
  • Access to optimized constants for more than 300 IOL models.

For the patient

  • Non-contact examination.
  • No topical anesthetic drops required for standard optical biometry.
  • Both eyes can be measured in less than 45 seconds.
  • Swept Source OCT enables optical biometry through many dense cataracts that may be difficult to measure with previous-generation optical biometers.
  • Most parameters required for IOL calculation can be acquired within a single diagnostic workflow.
Other equipmentThe full list of equipment is available here!

Reviews about the institute

See for yourself what people say about us

Clinic advantages

Kazakhstan’s first specialized ophthalmology institute

Extensive experience and the trust of patients from across Kazakhstan

Highly qualified specialists and an established scientific tradition

Modern equipment and advanced technologies

Articles

Other articlesThe full list of articles is available here!

Tests, games and exercises

More vision testsThe full list of vision tests is available here!

If you have any remaining questions

What can I contact KazRIED about?
You can contact the Kazakh Research Institute of Eye Diseases for the diagnosis and treatment of eye conditions. If you have concerns about your vision or need advice on an existing diagnosis, the appointment team can help you identify the appropriate service.
How do I book an appointment?
To book an appointment at KazRIED, use the contact details provided on the website. The appointment team will help you choose a specialist, check available times and explain the arrangements for your visit.
Do I need a referral from another doctor?
Referral requirements depend on the type of care and how it is accessed. When booking, please check whether you need a referral and which documents to prepare.
Can I book an eye examination for my child?
To check whether an appointment is available for your child, tell the appointment team your child’s age and the reason for the visit. They will advise you on the appropriate specialist and the documents to bring.
Which specialist should I book if I do not know why my vision has worsened?
If you do not yet have a diagnosis, describe your symptoms and the purpose of your visit when booking. The appointment team will help you choose an appropriate initial consultation, and the doctor will determine whether further tests or specialist consultations are needed.